Publication

fMRI at 1.5, 3 and 7 T: characterising BOLD signal changes

Résumé

Blood oxygenation level dependent (BOLD) signal changes occurring during execution of a simple motor task were measured at field strengths of 1.5, 3 and 7 T using multi-slice, single-shot, gradient echo EPI at a resolution of 1x1x3 mm(3), to quantify the benefits offered by ultra-high magnetic field for functional MRI. Using four different echo times at each field strength allowed quantification of the relaxation rate, R(2)* and the change in relaxation rate on activation, DeltaR(2). This work adds to previous studies of the field strength dependence of BOLD signal characteristics, through its: (i) focus on motor rather than visual cortex; (ii) use of single-shot, multi-slice, gradient echo EPI for data acquisition; (iii) co-registration of images acquired at different field strengths to allow assessment of the BOLD signal changes in the same region at each field strength. DeltaR(2) was found to increase linearly with field strength (0.51+/-0.06 s(-1) at 1.5 T; 0.98+/-0.08 s(-1) at 3 T; 2.55+/-0.22 s(-1) at 7 T), while the ratio of DeltaR(2)/R(2), which dictates the accessible BOLD contrast was also found to increase (0.042+/-0.002 at 1.5 T; 0.054+/-0.002 at 3 T; 0.084+/-0.003 at 7 T). The number of pixels classified as active, the t-value calculated over a common region of interest and the percentage signal change in the same region were all found to peak at TE approximately T(2) and increase significantly with field strength. An earlier onset of the haemodynamic response at higher field provides some evidence for a reduced venous contribution to the BOLD signal at 7 T.

À propos de ce résultat
Cette page est générée automatiquement et peut contenir des informations qui ne sont pas correctes, complètes, à jour ou pertinentes par rapport à votre recherche. Il en va de même pour toutes les autres pages de ce site. Veillez à vérifier les informations auprès des sources officielles de l'EPFL.

Graph Chatbot

Chattez avec Graph Search

Posez n’importe quelle question sur les cours, conférences, exercices, recherches, actualités, etc. de l’EPFL ou essayez les exemples de questions ci-dessous.

AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.