DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.
Marine oil spills can cause serious environmental damages to natural resources and to those whose sustenance depends upon these resources. Unfortunately experience shows that even the best efforts have not prevented occasional occurrences of major accident ...
Intube evaporation tests for R-407C and R-407C/oil are reported for a microfin tube. The tests were run at a nominal inlet pressure of 6.45 bar (93.5psia) at mass velocities of 100, 200 and 300 kg/m2s (73581, 147162 and 220743 lb/h ft2) over nearly the ent ...
Intube flow boiling experiments for refrigerant R-134a mixed with a lubricating oil are reported. The tests were run at a nominal inlet pressure of 3.4 bar over a wide range of vapor qualities at mass velocities of 100, 200 and 300 kg/m2s (73500, 147000 an ...
The Laboratory of Industrial Energy systems has evaluated a series of high performance air-water heat pump concepts with the aim to retrofit existing fuel fired boilers for residential hydronic heating systems. The results are published within the framewor ...
A summary of the objectives and conclusions reached in this project are: •A litterature search on post dryout heat transfer for pure refrigerants and for refrigerant-oil mixtures was performed and a comprehensive review written (Chapters 9, 10, and 11); •T ...
Hydrocarbon mass transfers to the atmosphere and water column drive the early weathering of oil spills and also control the chemical exposures of many coastal wildlife species. However, in the field, mass transfer rates of individual hydrocarbons to air an ...
A very high accuracy, straight vibrating tube type of density flow meter has been used online to measure oil concentraiton of flowing R-134a/oil mixtures. The calibrations covered oil concentrations from 0-6 wt.% oil over the temperature range from -9.4 to ...
The subject of this project is to develop a high performance air water heat pump which is able to be introducted in the retrofit market. The system requirements of this market are heating temperatures of 65°C, at ambient temperatures descending until -12°C ...