Isotachophoresis (ITP) is a technique in analytical chemistry used for selective separation and concentration of ionic analytes. It is a form of electrophoresis; charged analytes are separated based on ionic mobility, a quantity which tells how fast an ion migrates through an electric field. In conventional ITP separations, a discontinuous buffer system is used. The sample is introduced between a zone of fast leading electrolyte (LE) and a zone of slow terminating (or: trailing) electrolyte (TE). Usually, the LE and the TE have a common counterion, but the co-ions (having charges with the same sign as the analytes of interest) are different: the LE is defined by co-ions with high ionic mobility, while the TE is defined by co-ions with low ionic mobility. The analytes of interest have intermediate ionic mobility. Application of an electric potential results in a low electrical field in the leading electrolyte and a high electrical field in the terminating electrolyte. Analyte ions situated in the TE zone will migrate faster than the surrounding TE co-ions, while analyte ions situated in the LE will migrate slower; the result is that analytes are focused at the LE/TE interface. ITP is a displacement method: focusing ions of a certain kind displace other ions. If present in sufficient amounts, focusing analyte ions can displace all electrolyte co-ions, reaching a plateau concentration. Multiple analytes with sufficiently different ionic mobilities will form multiple plateau zones. Indeed, plateau mode ITP separations are readily recognized by stairlike profiles, each plateau of the stair representing an electrolyte or analyte zone having (from LE to TE) increasing electric fields and decreasing conductivities. In peak mode ITP, analytes amounts are insufficient to reach plateau concentrations, such analytes will focus in sharp Gaussian-like peaks. In peak mode ITP, analyte peaks will strongly overlap, unless so-called spacer compounds are added with intermediate ionic mobilities between those of the analytes; such spacer compounds are able to segregate adjacent analyte zones.

About this result
This page is automatically generated and may contain information that is not correct, complete, up-to-date, or relevant to your search query. The same applies to every other page on this website. Please make sure to verify the information with EPFL's official sources.

Graph Chatbot

Chat with Graph Search

Ask any question about EPFL courses, lectures, exercises, research, news, etc. or try the example questions below.

DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.