Pierluigi Bruzzone, Boris Stepanov
Two subsize, Nb3Sn cable-in-conduit conductors, are tested as short samples in the SULTAN test facility. Transverse load is applied by sweeping up and down the operating current in high background field. A serious performance loss of I, and n-factor is obs ...
2002