Lucky imaging (also called lucky exposures) is one form of speckle imaging used for astrophotography. Speckle imaging techniques use a high-speed camera with exposure times short enough (100 ms or less) so that the changes in the Earth's atmosphere during the exposure are minimal.
With lucky imaging, those optimum exposures least affected by the atmosphere (typically around 10%) are chosen and combined into a single image by shifting and adding the short exposures, yielding much higher angular resolution than would be possible with a single, longer exposure, which includes all the frames.
Images taken with ground-based telescopes are subject to the blurring effect of atmospheric turbulence (seen to the eye as the stars twinkling). Many astronomical imaging programs require higher resolution than is possible without some correction of the images. Lucky imaging is one of several methods used to remove atmospheric blurring. Used at a 1% selection or less, lucky imaging can reach the diffraction limit of even 2.5 m aperture telescopes, a resolution improvement factor of at least five over standard imaging systems.
File:zboo lucky image 1pc.png|[[Zeta Bootis]] imaged with the [[Nordic Optical Telescope]] on 13 May 2000 using the lucky imaging method. (The [[Airy disc]]s around the stars are [[diffraction]] from the 2.56 m telescope aperture.)
File:Zeta bootis short exposure.png|Typical short-exposure image of this binary star from the same dataset, but without using any [[speckle imaging|speckle]] processing. The effect of the Earth's atmosphere is to break the image of each star up into speckles.
The sequence of images below shows how lucky imaging works. From a series of 50,000 images taken at a speed of almost 40 images per second, five different long exposure images have been created. Additionally, a single exposure with very low image quality and another single exposure with very high image quality are shown at the beginning of the demo sequence. The astronomical target shown has the 2MASS ID J03323578+2843554.
This page is automatically generated and may contain information that is not correct, complete, up-to-date, or relevant to your search query. The same applies to every other page on this website. Please make sure to verify the information with EPFL's official sources.
In astronomy, seeing is the degradation of the of an astronomical object due to turbulence in the atmosphere of Earth that may become visible as blurring, twinkling or variable distortion. The origin of this effect is rapidly changing variations of the optical refractive index along the light path from the object to the detector. Seeing is a major limitation to the angular resolution in astronomical observations with telescopes that would otherwise be limited through diffraction by the size of the telescope aperture.
Speckle imaging comprises a range of high-resolution astronomical imaging techniques based on the analysis of large numbers of short exposures that freeze the variation of atmospheric turbulence. They can be divided into the shift-and-add ("image stacking") method and the speckle interferometry methods. These techniques can dramatically increase the resolution of ground-based telescopes, but are limited to bright targets.
The point spread function (PSF) describes the response of a focused optical imaging system to a point source or point object. A more general term for the PSF is the system's impulse response; the PSF is the impulse response or impulse response function (IRF) of a focused optical imaging system. The PSF in many contexts can be thought of as the extended blob in an image that represents a single point object, that is considered as a spatial impulse. In functional terms, it is the spatial domain version (i.e.
Explores the complexity of boundary plasma in fusion energy research, focusing on experimental techniques and simulations to understand plasma dynamics and improve fusion reactor design.
Explores neocortical neuron classification, ion channel kinetics, challenges in modeling individual cells, and data integration.
Covers advanced operation techniques for a Transmission Electron Microscope (TEM), including setting up the workset and fine-tuning the image.
The time-resolved visualization of the dynamics of a cavitation bubble usually requires the use of expensive high-speed cameras, which often provide a limited spatial resolution. In the present study, we propose an alternative to these high-speed imaging t ...
Pixelation is common in quantum imaging systems and limit the image spatial resolution. Here, the authors introduce a pixel super-resolution approach based on measuring the full spatially-resolved joint probability distribution of spatially-entangled photo ...
NATURE PORTFOLIO2022
, , ,
We present a pipeline for the automatic generation of digital twins of free-standing buildings for damage assessment. Our method takes multiple view images of the target building as input and processes them to produce a 3D model in levels of detail (LOD) f ...