Purpose: Phosphorus MRS (31P MRS) enables noninvasive assessment of energy metabolism, yet its application is hindered by sensitivity limitations. To overcome this, often high magnetic fields are used, leading to challenges such as spatial (Formula present ...
Objective: This study evaluates the performance of a twisted pair transmission line coil as a transceive element for 7 T MRI in terms of physical flexibility, robustness to shape deformations, and interelement decoupling. Methods: Each coil element was cre ...
A new and efficient magnetisation transfer P-31 magnetic resonance fingerprinting (MT-P-31-MRF) approach is introduced to measure the creatine kinase metabolic rate kCKkCK between phosphocreatine (PCr) and adenosine triphosphate (ATP) i ...
The literature reports on radiofrequency (RF) transmit (Tx) elements tailored for ultrahigh-field (UHF) magnetic resonance imaging (MRI) showed confounded reproducibility due to variations in simulation tools, modeling assumptions, and meshing techniques. ...
PurposeTo implement a flexible framework, named HydrOptiFrame, for the design and optimization of time-efficient water-excitation (WE) RF pulses using B-spline interpolation, and to characterize their lipid suppression performance. MethodsAn evolutionary o ...
The present invention relates to a system (1) for combined transcranial focused ultrasound and magnetic resonance imaging, comprising: a plurality of dielectric resonator antennas (2), each dielectric resonator antenna (2) comprising a dielectric medium (2 ...
PurposeIn this study, we aimed to measure the apparent diffusion coefficients (ADCs) of major phosphorous metabolites in the human calf muscle at 7 T with a diffusion-weighted (DW)-STEAM sequence.MethodsA DW-STEAM sequence with bipolar gradients was implem ...
Nicotinamide Adenine Dinucleotide (NAD) plays a central role in the master circadian clock of the brain (the suprachiasmatic nuclei, SCN) as demonstrated in many model organisms. NAD acts as an enzyme co-factor and substrate and its modulation was found to ...
Purpose: To introduce the dipolectric antenna: a novel RF coil design for high-field MRI using a combination of a dipole antenna with a loop-coupled dielectric resonator antenna. ...
ObjectiveTo determine whether a multi-feed, loop-dipole combined approach can be used to improve performance of rectangular dielectric resonator antenna (DRA) arrays human brain for MRI at 7 T.Materials and methodsElectromagnetic field simulations in a sph ...