An imbalance in the transport current among the strands of a Cable-in-Conduit conductors (CICC) can be associated with the change of their performance. In order to understand and improve the performance of CICC's, it is essential to study the current imbalance. This paper focuses on the study of the current imbalance in two short samples of the SeCRETS (Segregated Cooper Ratio Experiment on Transient Stability) conductors subjected to a cyclic load in the SULTAN facility. The self field around the conductors was measured on four locations by 32 miniature Hall sensors for a reconstruction of the current distribution. The results of the self field measurements in the DC tests are presented and discussed.
Kamil Sedlák, Nikolay Bykovskiy, Roberto Guarino