Computations of AC loss in the ITER magnets, during fast field transients
Graph Chatbot
Chat with Graph Search
Ask any question about EPFL courses, lectures, exercises, research, news, etc. or try the example questions below.
DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.
Flexible AC Transmission Systems (FACTS) are systems based on power electronics using GTO or IGCT semiconductors [1] that allow a better use of the transfer capacities of the transmission lines and permit to satisfy the requirements due to the liberalizati ...
This paper examines the use of thyristor controlled series capacitors (TCSCs) for the redistribution of active power flows (PFs) in a transmission network and presents a simple model of a hierarchical coordinated control system for multiple devices. The TC ...
The cable-in-conduit superconductors are preferred for applications where the AC losses and stability are a major concern, e.g., fusion magnets and SMES. A review of coupling currents loss results for both NbTi and Nb3Sn cable-in-conduit conductors (CICC) ...
The digital transient torque measuring device presented in this paper is able to make a "real time" calculation in steady-state and transient conditions of the electromagnetic torque or force of an extremely wide range of ac electrical machines supplied wi ...
The coupling current-losses of a full size, fusion dedicated Nb3Sn cable-in-conduit superconductor are measured as a function of the transverse load in the SULTAN III test facility. Applying a broad range of transport current (up to 56 kA) and background f ...
The coupling current-losses of a full size, fusion dedicated Nb3Sn cable-in-conduit superconductor are measured as a function of the transverse load in the SULTAN III test facility. Applying a broad range of transport current (up to 56 kA) and background f ...
This paper describes the numerical simulation of the stator currents, flux and torque controls of an AC motor. The control priciple used is based on the orientation on the rotor flux. The originality of this simulation consists in the method used to simula ...
Up to now, preventive or corrective actions to improve power systems' operating states mainly concern power generation rescheduling, load-shedding and tap modifications of in-phase or phase-angle transformers. A method is proposed for relieving overloads b ...