DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.
The scope of this thesis encompasses two main subjects: fixed-structure data-driven control design on one side, and control design in power systems on the other. The overall goal is to identify challenging and relevant problems in power systems, to express ...
Control systems operating in real-world environments often face disturbances arising from measurement noise and model mismatch. These factors can significantly impact the perfor- mance and safety of the system. In this thesis, we aim to leverage data to de ...
The objective of this dissertation is to develop data-driven frequency-domain methods for designing robust controllers through the use of convex optimization algorithms. Many of today's industrial processes are becoming more complex, and modeling accurate ...
In this paper, we propose a novel time-varying feedback control strategy based on the Robust Integral of the Sign of the Error (RISE). The main motivation is to enhance the tracking performance of RISE controller at high dynamic operating conditions. RISE ...
A new robust controller design method that satisfies the H-infinity criterion is developed for linear time-invariant single-input single-output (SISO) systems. A data-driven approach is implemented in order to avoid the unmodeled dynamics associated with p ...
The inter-area oscillations are common in power systems and can occur due to the changes in the load or generating power especially in long transmission lines. This paper presents the design of a robust fixed order loop shaping controller to damp out the i ...
At present, most of the magnetic bearing system adopts the classical proportional-integral-derivative (PID) control strategy. However, the external disturbances, system parameter perturbations, and many other uncertain disturbances result in PID controller ...
The frequency response data of a generalized system is used to design fixed-structure controllers for the H2 and H∞ synthesis problem. The minimization of the two and infinity norm of the transfer function between the exogenous inputs and performance outpu ...
In this paper, a data-driven method for controller design with constraints on the positive-realness of closed-loop transfer functions over an arbitrary set of frequencies is proposed. The positive-realness of a closed-loop transfer function is represented ...
We study the problem of performance optimization of closed -loop control systems with unmodeled dynamics. Bayesian optimization (BO) has been demonstrated to be effective for improving closed -loop performance by automatically tuning controller gains or re ...