DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.
An experimental study on flow boiling pressure drop and heat transfer of a new environmentally friendly refrigerant R1233zd(E), in a parallel multi-microchannel evaporator was carried out. The silicon microchannels evaporator was 10 mm long and 10 mm wide, ...
In the second article of the present two-part paper, upward single-phase heat transfer within a compact plate heat exchanger was investigated experimentally. The experimental setup, the data reduction technique and pressure drop results were presented in P ...
Multi-microchannel evaporators used for the cooling of high heat flux electronics have been of interest to both industry and academia for more than a decade. Such interest has sparked a large number of research studies on the flow boiling pressure drop and ...
This study is devoted to complex experimental investigation of two-phase flow boiling of R134a refrigerant in a minichannel having a hydraulic diameter of 540 μm at heat fluxes up to 70 kW/m2 and mass fluxes up to 700 kg/(m2 s). Flow regimes, pressure drop ...
In this work flow visualizations and measurements are made and analyzed to identify flow regime transitions, slug-to-intermittent, intermittent-to-annular and the dry-out inception, during the flow boiling of CO2 in a horizontal smooth tube of 6.00 mm of i ...
This article presents new experimental critical heat flux results under saturated flow boiling conditions for a macro/microscale tube. The data were obtained in a horizontal 2.20-mm inside diameter stainless-steel tube with heating lengths of 361 and 154 m ...
New enhanced boiling tubes from Wolverine Tube Inc. (Turbo-B5) and Wieland-Werke AG (Gewa-B5) were investigated using R-134a and R-236fa as test fluids. The tests were done at saturation temperatures of 5 and 15 degrees C, mass flow rates from 4 to 35 kg m ...
Elsevier Sci Ltd2014
,
Boiling heat transfer in microchannels has been investigated extensively in the last two decades. However, most results from independent experimental studies display a substantial disagreement on the influence of the flow conditions and mechanisms on the h ...
In this paper, new saturated critical heat flux (CHF) values at medium-to-high saturation temperatures are presented for an aluminum multi-minichannel test section. Among the possible working fluids, R134a and the low GWP refrigerants R1234yf and R1234ze h ...
The pressure drops of external flow over enhanced tube bundles were experimentally obtained at both adiabatic and diabatic conditions using R-134a and R-236fa as test fluids. The tests were carried out at saturation temperatures of 5 and 15 degrees C, mass ...