TEM cell testing of cable noise reduction techniques from 2 MHz to 200 MHz - Part 1
Graph Chatbot
Chat with Graph Search
Ask any question about EPFL courses, lectures, exercises, research, news, etc. or try the example questions below.
DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.
Information for phase identification may be gathered in the electron transmission microscope with spatial resolution down to the nanometre scale. Energy dispersive X-ray and electron energy loss spectrometries are based on inelastic electron/sample interac ...
Crystal damage induced by irradiation is investigated using transmission electron microscopy (TEM) coupled to molecular dynamics (MD) calculations. The displacement cascades are simulated for energies ranging from 10 to 50 keV in Al, Ni and Cu and for time ...
The core–shell structure of a range of acrylic–acrylic latexes has been investigated by combining different specimen preparation methods with transmission electron microscopy (TEM), dark-field scanning transmission electron microscopy (DSTEM) and low-volta ...
The core–shell structure of a range of acrylic–acrylic latexes has been investigated by combining different specimen preparation methods with transmission electron microscopy (TEM), dark-field scanning transmission electron microscopy (DSTEM) and low-volta ...
Hydrophobins self assemble into amphipathic films at hydrophobic-hydrophilic interfaces. These proteins are involved in a broad range of processes in fungal development. We have studied the conformational changes that accompany the self-assembly of the hyd ...
Building upon the similarities between inelastic electron scattering and X-ray absorption we show that dichroism can be observed in electron energy loss spectrometry (EELS) in the transmission electron microscope (TEM). Natural or magnetic linear dichroism ...
The characterization of sub-micron gratings is usually performed on scanning electron microscopes, although the dimensions of the features often make the observations difficult. We report here on a new method applicable to III-V and II-VI semiconductors: w ...
An energy filter receiving an electronic beam oriented along an optical axis. The filter includes a deflecting system which deviates in a dispersion plane not including the optical axis the received beam and a dispersing system which guides the beam sent b ...
By means of transmission electron microscopy (TEM) the structure of chemically ordered regions in Zr-doped Pb(Mg1/3Ta2/3)O-3 has been studied. Large coherent ordered domains were obtained by the addition of 5 mol% PbZrO3. The results obtained by convention ...
A comparative image simulation and transmission electron microscopy (TEM) study has been addressed in order to assess whether NiAl intermetallic undergoes a crystalline-to-amorphous transformation directly induced by the cascade. For this purpose, an NiAl ...