The "systolic volume balance" method for the noninvasive estimation of cardiac output based on pressure wave analysis
Graph Chatbot
Chat with Graph Search
Ask any question about EPFL courses, lectures, exercises, research, news, etc. or try the example questions below.
DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.
METHODOLOGY: A new non-invasive ultrasonic device was developed to characterize the biomechanical properties of medium and large peripheral arteries. Simultaneous recordings of internal diameter and blood pressure over the whole cardiac cycle are used to e ...
We derived and tested a new, simple, and accurate method to estimate the compliance of the entire arterial tree and parts thereof. The method requires the measurements of pressure and flow and is based on fitting the pulse pressure (systolic minus diastoli ...
Seven classic and recently proposed methods used for the estimation of total arterial compliance have been evaluated for their accuracy and applicability in different physiological conditions. The pressure and flow data are taken from a computer model that ...
A computer model for simulating pressure and flow propagation in the human arterial system is developed. The model is based on the one-dimensional flow equations and includes nonlinearities arising from geometry and material properties. Fifty-five arterial ...
AIM: Non-invasive measurements of arterial diameter and wall thickness are critical in characterizing the onset and development of vascular disease. A precise dynamic method was proposed and tested for this purpose. DESIGN: A non-invasive method of measuri ...
The non-linear elastic response of arteries implies that their mechanical properties depend strongly on blood pressure. Thus, dynamic measurements of both the diameter and pressure curves over the whole cardiac cycle are necessary to characterise properly ...
We investigated how parameters describing the heart and the arterial system contribute to the systolic and diastolic pressures (Ps and Pd, respectively) and stroke volume (SV). We have described the heart by the varying-elastance model with six parameters ...
We investigated the patterns of vasomotion in various conduit arteries of the human arm. The internal diameter of the brachial, radial, ulnar, and digital artery was measured noninvasively in 17 healthy volunteers (aged 24-40 yr), using a high-precision ul ...