Performance and Profitability Perspectives of a CO2 based District Energy Network in Geneva’s City Center
Graph Chatbot
Chat with Graph Search
Ask any question about EPFL courses, lectures, exercises, research, news, etc. or try the example questions below.
DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.
The analysis of cooling of a binary HTS 20 kA current lead (CL) operating between 4.5 and 300 K has been carried out. Assuming that the HTS module is conduction-cooled, two cooling options for the copper heat exchanger (HEX) part of the CL have been consid ...
A new district energy network has been developed by using CO2 as a heat transfer fluid. Only two pipes are required by the network, thus allowing the recovery of waste heat from the cooling users to be valorized by the heating users. Understanding and pred ...
Hot-spots are present in micro-electronics and are challenging to cool effectively. This paper presents highly nonuniform heat flux measurements obtained for a pseudo-CPU with 35 local heaters and temperature sensors cooled by a silicon multi-microchannel ...
In the general frame of Compressed Air Energy Storage system (CAES), the LEI Laboratory of EPFL has introduced the concept of dry finned piston. The main goal is to achieve energy storage by means of compressed air thanks to high isothermal efficiency comp ...
Structural fire endurance experiments were conducted on full-scale cellular glass fiber-reinforced (GFRP) columns under axial compression and subjected to ISO834 fire exposure from one side. Unprotected columns can resist fire for more than 30 min, which i ...
Cooling of datacenters is estimated to have an annual electricity cost of 1.4 billion dollars in the United States and 3.6 billion dollars worldwide. Currently, refrigerated air is the most widely used means of cooling datacenter’s servers, which typically ...
Neighbourhood energy concepts for mixed industrial and commercial sites can be developed by applying energy integration techniques. This study presents an application of these techniques on a concrete site (RTA facility in Vienna, Austria), focussing on th ...
The analysis of cooling of a binary HTS 20 kA current lead (CL) operating between 4.5 and 300 K has been carried out. Assuming that the HTS module is conduction-cooled, two cooling options for the copper heat exchanger (HEX) part of the CL have been consid ...
The Advanced Single-stage Planar Actuator (ASPA) is a nanometer-accurate magnetically levitated planar actuator with moving magnets. It is designed at the Eindhoven University of Technology in collaboration with an industrial partner active in the semicond ...
Due to the increase in energy prices and spiralling consumption, there is a need to greatly reduce the cost of electricity within data centers, where it makes up 50% of the total cost of the IT infrastructure. A technological solution to this is using on-c ...