A Novel Approach to Reducing Number of Sensing Units for Wearable Gait Analysis Systems
Related publications (49)
Graph Chatbot
Chat with Graph Search
Ask any question about EPFL courses, lectures, exercises, research, news, etc. or try the example questions below.
DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.
The mode of action of RG-hydrolase and RG-lyase toward purified linear rhamnogalacturonan (RG) oligomers has been studied. Major tools in the characterization of the degradation products were the exo-acting RG-rhamnohydrolase and RG-galacturonohydrolase. T ...
Comprehensive gait analysis usually includes kinematics, kinetics, and electromyography. A complex instrumentation is thus required that only can be installed in a dedicated laboratory. These techniques are valuable to support clinical decisions and to eva ...
A theoretical model and numerical methods were developed for testing different bone internal remodelling stimuli. The keystone of the study was the formulation of a stimulus based on the mechanical invariants of the stress tensor, which took into account b ...
A new method for the detection of gait cycle phases using only two miniature accelerometers together with a light, portable digital recorder is proposed. Each subject is asked to walk on a walkway at his/her own preferred speed. Gait analysis was performed ...
Purpose of the study After total hip replacement, the initial stability of the cementless femoral stem is a prerequisite for ensuring bone ingrowth and therefore long term fixation of the stem. For custom made implants, long term success of the replacement ...
Rayleigh backscattering measurements on a fiber ring resonator enables to monitor loss and gyroscopic motion experienced by the ring. This easy-to-use technique yields to very sensitive fiber loss sensors and polarization-insensitive and low-cost gyroscope ...
Society of Photo-Optical Instrumentation Engineers1999
In this paper a new method for gyroscopic sensitivity evaluation of a vibrating angular rate sensor is presented. This method is used to evaluate the angular rate sensitivity of a four-beam-bridge gyroscope realized at IMT Neuchatel [ii. The frequency spli ...
A novel kind of fiber-optic gyroscope based on Rayleigh backscattering in a fiber-ring resonator is presented in this letter. Information on the rotation rate is obtained from the composed response of the fiber ring to an optical time-domain reflectometry ...
When treated with BuLi in the presence of Na or K tert-butoxide, 2-(trimethylsilyl)- and 2-(triethylsilyl)norbornadiene undergo H/metal-exchange mainly at the 5-position. The latter position is slightly activated relative to unsubstituted norbornadiene whi ...