Conductor Performance Qualification of TFKO3 Sample for ITER TF Magnet
Related publications (33)
Graph Chatbot
Chat with Graph Search
Ask any question about EPFL courses, lectures, exercises, research, news, etc. or try the example questions below.
DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.
From February 2007 to May 2008, 18 short length conductor sections have been tested in SULTAN for design verification and manufacturer qualification of the ITER Toroidal Field (TF) conductor. The test program is focussed on the current sharing temperature, ...
The coupling current loss in rectangular superconducting cables is strictly dependent on their aspect ratio, which has an impact on the area linked by the field variation and consequently on the currents induced between strands. The relation between the ac ...
In the framework of the ITER qualification tests the second Chinese sample (CNTF2) was tested in the SULTAN facility. The sample was made of two identical ITER TF type cable-in-conduit conductor sections. Internal Sn strands offered by Western Superconduct ...
Within the framework of the European Fusion Programme a FSJS has been designed and manufactured by European Industry using PF coil NbTi superconductor manufactured and supplied by the Russian Federation as part of the R&D for the PF Conductor Insert (PFCI) ...
A short sample of the NbTi cable-in-conduit conductor (CICC) manufactured for the ITER PF insert coil has been tested in the SULTAN facility at CRPP. The short sample consists of two paired conductor sections, identical except for the sub-cable and outer w ...
Two full-size conductor samples using advanced Nb3Sn strands were tested in the SULTAN facility in 2005-2006 within (I,B,T) ranges close to the ITER operating conditions (B-MAX similar to 12 T, T similar to 5 K). Each sample includes two conductor legs, co ...
Two short length samples have been prepared and tested in SULTAN to benchmark the performance of high current density, advanced Nb3Sn strands in the large cable-in-conduit conductors (CICC) for ITER. The cable pattern and jacket layout were identical to th ...
A complete framework dealing with power line communication in medium voltage network is proposed. Based on path loss measurements, a complete characterisation of inductive couplers is performed. After a brief recall of inductive coupling techniques, we add ...
Within the R&D program on the International Thermonuclear Experimental Reactor (ITER) Poloidal Field (PF) coils, a full size conductor sample was tested in the SULTAN facility (CRPP Villigen, Switzerland). This sample is composed of two straight ITER-like ...
The preparative experimental and analysis work as well as the code development for testing the ITER (International Thermonuclear Experimental Reactor) TFMC, one of the large projects of the ITER research and development programme, is described. The expecte ...