Building envelopes – A permeable interface for daylight and solar harvesting
Graph Chatbot
Chat with Graph Search
Ask any question about EPFL courses, lectures, exercises, research, news, etc. or try the example questions below.
DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.
Dynamic simulation is an accurate but time-consuming way tu calculate energy and thermal comfort performances of passive solar buildings. Simplified methods, originally developed to evercome their disadvantage, unfortunately do not provide the same quantit ...
Within the European research project HOPE, a multi-disciplinary study was performed in nine European countries, by auditing 160 apartments and office buildings, of which half of them can be characterised as having low energy use. The investigating tools we ...
Physical models are commonly used to assess daylighting performance of buildings using sky simulators for purpose of research as well as practice. Recent studies have pointed out the general tendency of scale model assessments to overestimate the performan ...
Physical models are commonly used to assess daylighting performance of buildings using sky simulators for purpose of research as well as practice. Recent studies have pointed out the general tendency of scale model assessments to overestimate the performan ...
Efficient collection and redistribution of the direct and diffuse components of daylight in buildings remains a major objective of advanced fenestration systems. Such systems, including novel solar blinds, new glazing or coating materials and daylight-redi ...
To describe complex fenestration systems such as novel solar blinds, new glazing or coating materials, daylight and sunlight-redirecting devices, a detailed description of their optical properties is needed, given by their Bidirectional Transmission (or Re ...
Stochastic models for the analysis of the energy and thermal comfort performances of passive solar devices have benn increasingly studied for over a decade. A new approach to thermal building modelling, based on Markov chains, is proposed here to combine b ...
Recent studies have pointed out the general tendency of scale models to overestimate the daylighting performance of buildings, usually expressed through work plane illuminance and daylight factor distribution profiles. An analysis of the corresponding sour ...