Optimization of the Start-up Time of a Variable Speed Pump-Turbine Unit in Pumping Mode
Graph Chatbot
Chat with Graph Search
Ask any question about EPFL courses, lectures, exercises, research, news, etc. or try the example questions below.
DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.
Electric motors consume over half of the electrical energy produced by power stations, almost the three-quarters of the electrical consumption in industry and almost the half of commercial electrical consumption in developed countries. Motors are by far th ...
An unbalanced DC-link voltage regulation strategy is proposed for a three-level voltage source inverter used in the rotor cascade of a double-fed asynchronous motor-generator. The major problem in determining the presence of the unbalanced component is inv ...
Developments trends in commercial drives point that that the next generation of them includes some sort of sensorless torque control. Using the 'spare' processing power of a digital signal processor (DSP) to implement these techniques can significantly red ...
Usually, each phase of the direct reluctance motor is fed separately by its own inverter producing a squarewave phase current depending on the rotor position. In the present work, a star-connection of the three stator phases is used and the direct reluctan ...
The use of a static frequency converter which is inserted between the grid and the stator is a well known solution to achieve an adjustable speed machine. Adjustable speed drive systems have already been applied in the past to hydro power plants. Up to now ...
In recent years the use of solid state frequency converters is rapidly increasing in the industrial and power plants where electric machines are installed, since it allows variable speed operations for the electric system, thus becoming a key factor which ...
This paper deals with a fixed-frequency variable-speed motor/generator with 3-level VSI (Voltage Source Inverter) cascade. The 3-level VSI is applied to a DASM (Doubly-fed ASynchronous Machine) for large pump storage plants. The extension to 3 levels is th ...
In a concern for sustainable development, the rational use of electrical energy implies having transportation networks capable of transmitting large quantities of electrical energy over long distances as well as adequate storage plants. This double require ...
The paper deals with the main problems to solve in order to simulate precisely the behavior of complex power systems with mixed elements (power components and digital regulation devices). A simulation tool developed at the Swiss Federal Institute of Techno ...
The paper deals with the main problems to solve in order to simulate precisely the behavior of complex power systems with mixed elements (power components and digital regulation devices). The main features of an efficient simulation tool are described. The ...