Publication

Experimental study at prototype scale of a self-priming free surface siphon

Giovanni De Cesare, Paloma Furlan
2017
Conference paper
Abstract

This study is within the frame of the construction of the rail link between Geneva Cornavin station, Eaux-Vives station and Annemasse (CEVA). The project area is located at a cut-and-cover tunnel built by slurry walls located in the alluvium of the Foron River. The installation of the covered trench cuts the groundwater table flow, which causes a rise of the water table in spite of the partial evacuation by the Foron. It is therefore planned to add about thirty wells in order to transit the waters of the aquifer from one side of the tunnel to the other. A thorough reflection allowed to find an alternative solution to traditional pumping consisting of putting in place self-priming multiphase siphons which forms the basis of the following study. The operating principle of the system is based on the maintenance of a free-surface vortex in a vacuum in what will be called the sealed box which functions by keeping the siphon primed to allow water to be transferred from either side of the gallery. This study explores the performance of a physical model of the system with the following objectives: (1) To characterize the initiation and stability conditions of the system by maintaining the vacuum in the sealed box and (2) to characterize the limiting operating conditions of the system in relation to the ground water table levels which relates to insufficient air entrainment due to low outflow or submergence of the sealed box. The experimental installation is fabricated at a scale of 1:1 so as not to introduce scale effects by the presence of air, the water-air mixture and the free-surface vortex in a vacuum atmosphere.

About this result
This page is automatically generated and may contain information that is not correct, complete, up-to-date, or relevant to your search query. The same applies to every other page on this website. Please make sure to verify the information with EPFL's official sources.
Related concepts (32)
Water table
The water table is the upper surface of the zone of saturation. The zone of saturation is where the pores and fractures of the ground are saturated with water. It can also be simply explained as the depth below which the ground is saturated. The water table is the surface where the water pressure head is equal to the atmospheric pressure (where gauge pressure = 0). It may be visualized as the "surface" of the subsurface materials that are saturated with groundwater in a given vicinity.
Tunnel
A tunnel is an underground passageway, dug through surrounding soil, earth or rock, and enclosed except for the entrance and exit, commonly at each end. A pipeline is not a tunnel, though some recent tunnels have used immersed tube construction techniques rather than traditional tunnel boring methods. A tunnel may be for foot or vehicular road traffic, for rail traffic, or for a canal. The central portions of a rapid transit network are usually in the tunnel.
Groundwater
Groundwater is the water present beneath Earth's surface in rock and soil pore spaces and in the fractures of rock formations. About 30 percent of all readily available freshwater in the world is groundwater. A unit of rock or an unconsolidated deposit is called an aquifer when it can yield a usable quantity of water. The depth at which soil pore spaces or fractures and voids in rock become completely saturated with water is called the water table.
Show more
Related publications (33)

rrechaRge an R package for integrated groundwater recharge modelling

Emmanuel Qays Dubois

Context • Groundwater major water resource throughout the world that is heterogeneously distributed and sustains diversified uses • The sustainability of groundwater usage highly dependent on the relative rates of groundwater abstraction e g via pumping) a ...
2024

Nature-based solution enhances resilience to flooding and catalyzes multi-benefits in coastal cities in the Global South

Jérôme Chenal, Paolo Perona, Charlotte Grossiord, Emmanuel Qays Dubois, Montana Marshall

Coastal cities are facing a rise in groundwater levels induced by sea level rise, further triggering saturation excess flooding where groundwater levels reach the topographic surface or reduce the storage capacity of the soil, thus stressing the existing i ...
2024

Impacts of climate change on Swiss alluvial aquifers - A quantitative forecast focused on natural and artificial groundwater recharge by surface water infiltration

Sebastiano Piccolroaz

The sensitivity of future groundwater recharge and temperature development was investigated for three alluvial aquifers in the urban agglomeration of the city of Basel, Switzerland. For selected climate projections groundwater recharge and the associated t ...
ELSEVIER2022
Show more

Graph Chatbot

Chat with Graph Search

Ask any question about EPFL courses, lectures, exercises, research, news, etc. or try the example questions below.

DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.