Seismic Performance Evaluation and Retrofit of Existing Steel Frame Buildings
Graph Chatbot
Chat with Graph Search
Ask any question about EPFL courses, lectures, exercises, research, news, etc. or try the example questions below.
DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.
A unidirectional shake-table test was performed on the half-scale prototype of a natural stone masonry building aggregate, to investigate the seismic performance of this type of historical construction and to assess the effectiveness of two retrofit soluti ...
The seismic assessment of masonry buildings, both modern unreinforced masonry (URM) buildings and historical heritage constructions, is a complex task, characterised by a several sources of uncertainty, which regard the appropriate modelling of strategy th ...
Performance-based earthquake engineering (PBEE) has become an increasingly popular framework to design, retrofit and manage structures. This probabilistic framework integrates data from the seismic hazard, structural response, damage fragility and damage c ...
Hybrid simulations were conducted to evaluate the system-level seismic response of a 4-story steel moment frame building and its gravity framing system through various levels of ground motion shaking. The experimental substructure examined in detail corres ...
Assessing seismic vulnerability at large scales requires accurate attribution of individual buildings to more general typological classes that are representative of the seismic behavior of the buildings sharing same attributes. One-by-one evaluation of all ...
Concentrically Braced Frames (CBFs) built before the introduction of the capacity design concept do not usually meet modern seismic design requirements. They are vulnerable to seismic events and they could develop unpredictable failure mechanisms. An exist ...
Steel lateral load-resisting systems offer a variety of design solutions to ensure a ductile behaviour of a structure during a seismic event, thereby achieving a relatively low earthquake-induced collapse risk, if designed and detailed properly according t ...
Centre suisse de la construction métallique (SZS)2019
Fling-step and forward directivity are the major consequences of near-fault ground motions as they can impose unexpected seismic demands on structures located in the vicinity of the fault. The pernicious effect of forward directivity on the seismic behavio ...
Induced (and triggered) seismicity following fluid injections at depth, is governed by pore pressure diffusion. Interestingly, recent studies yield unrealistically large values of diffusivity in order to explain the timing of the generated seismicity. We i ...
A unidirectional shaking-table test on the half-scale prototype of a natural stone masonry building aggregate was performed as part of an extensive experimental and numerical research project, investigating the seismic vulnerability of historical buildings ...