Two-Phase Flow Simulations within Plate Heat Exchangers
Graph Chatbot
Chat with Graph Search
Ask any question about EPFL courses, lectures, exercises, research, news, etc. or try the example questions below.
DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.
Improving the energy efficiency of cooling systems can contribute to reduce the emission of greenhouse gases. Currently, most microelectronic applications are air-cooled. Switching to two-phase cooling systems would decrease power consumption and allow for ...
This paper presents numerical simulations of annular laminar film condensation heat transfer in microchannels of different internal shapes. The model, which is based on a finite volume formulation of the Navier-Stokes and energy equations for the liquid ph ...
Experimental condensation heat transfer data for the new refrigerant R1234ze(E), trans-1,3,3,3-tetrafluoropropene, are presented and compared with refrigerants R134a and R236fa for a vertically aligned, aluminum multi-port tube. Local condensation heat tra ...
Heat transfer coefficients for enhanced tubes are typically measured indirectly using the "Wilson plot" method to first characterize the thermal performance of the one side (heating or cooling supply) and then to obtain the heat transfer data for the enhan ...
The analysis of cooling of a binary HTS 20 kA current lead (CL) operating between 4.5 and 300 K has been carried out. Assuming that the HTS module is conduction-cooled, two cooling options for the copper heat exchanger (HEX) part of the CL have been consid ...
The analysis of cooling of a binary HTS 20 kA current lead (CL) operating between 4.5 and 300 K has been carried out. Assuming that the HTS module is conduction-cooled, two cooling options for the copper heat exchanger (HEX) part of the CL have been consid ...
Two-phase flow operational stability of refrigerants R245fa, R236fa, and R1234ze(E) in 100 x 100 μm2 multi-microchannels for cooling of future high-performance 3D stacked architectures with interlayer cooling has been addressed in the current experimental ...
The operation of the Large Hadron Collider calls for a thorough analysis of the thermo-electric behavior of the 13 kA superconducting bus-bars connecting its dipole and quadrupole main magnets. This presentation reports a synthesis of the work performed jo ...
The present report describes the work realized in the frame of a Mas- ter Pro ject in collaboration between the company EnBW Energie Baden- Württemberg AG (Germany) and the Section of Mechanical Engineering of the Swiss Institute of Technology of Lausanne ...
The analysis of cooling of a binary high T-c superconductor (HTS) 20 kA current lead (CL) operating between 4.5 and 300 K is carried out. We assume that the HTS module is conduction cooled, whereas the cold end of the copper heat exchanger (HEX) is immerse ...