Fast model-based T-2 mapping using SAR-reduced simultaneous multislice excitation
Graph Chatbot
Chat with Graph Search
Ask any question about EPFL courses, lectures, exercises, research, news, etc. or try the example questions below.
DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.
With improved B-0 homogeneity along with satisfactory gradient performance at high magnetic fields, snapshot gradient-recalled echo-planar imaging (GRE-EPI) would perform at long echo times (TEs) oil the order of T-2*, which intrinsically allows obtaining ...
Objectives: Sixty three healthy subjects were measured to assess dependence of brain metabolites on age using short- and long echo time spectroscopy in different brain regions. Material and methods: Younger and elderly humans were measured with long echo t ...
Echo-planar imaging (EPI) is a fast nuclear magnetic resonance imaging (MRI) method. Unfortunately, local magnetic field inhomogeneities induced mainly by the subject's presence cause significant geometrical distortion, predominantly along the phase-encodi ...
Ability to peer into human body is an essential diagnostic tool in medicine. Out of the four major imaging modalities that include ultra-sound, magnetic resonance imaging (MRI), and positron emission tomography (PET), nuclear medicine is gaining more wides ...
A dynamic nuclear polarization prepolarizer was developed and coupled to a 9.4 T rodent magnetic resonance imaging scanner in order to perform in vivo hyperpolarization experiments. In the present paper, emphasis is put on methods and hardware performance ...
Measurements of T2 relaxation times in tissues have provided a unique, noninvasive method to investigate the microenvironment of water molecules in vivo. As more clinical imaging is performed at higher field strengths, tissue relaxation times need to be re ...
Nine subjects were studied by high-speed magnetic resonance imaging while performing language-based tasks. Subjects were asked either to repeat or to generate verbs associated with nouns read by an experimenter while magnetic resonance images were obtained ...
Ability to peer into human body is an essential diagnostic tool in medicine. Out of the four major imaging modalities that include ultra-sound, magnetic resonance imaging (MRI), and positron emission tomography (PET), nuclear medicine is gaining more wides ...
During the last two decades, magnetic resonance imaging (MRI) has evolved into one of the most powerful techniques in medical diagnosis. Among the various medical diagnostic modalities, such as X-ray or ultra-sound imaging, MRI is the technique of choice e ...
n a previous paper, we reported the first longitudinally detected electron paramagnetic resonance (LODEPR) measurements of fast T1e values in aqueous solutions of two Gd3+ chelates, and we included predicted values for these relaxation times, based on zero ...