Experimental Characterization of Different Condenser Technologies in a Passive Two-Phase Cooling System for Thermal Management of Electronics
Graph Chatbot
Chat with Graph Search
Ask any question about EPFL courses, lectures, exercises, research, news, etc. or try the example questions below.
DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.
Thermal designers of data centers and server manufacturers are showing a greater concern regarding the cooling of the new generation data centers, which consume considerably more electricity and dissipate much more waste heat, a situation that is creating ...
Growing demands for increased functionality in consumer electronics and for information technology-enabled services in various sectors have resulted in the rise of high-performance multiprocessor system-on-chips (MPSoCs) and three-dimensionally stacked int ...
A theoretical and numerical model to predict film condensation heat transfer in mini, micro and ultra micro-channels of different internal shapes is presented in this thesis. The model is based on a finite volume formulation of the Navier-Stokes and energy ...
Cooling of datacenters is estimated to have an annual electricity cost of 1.4 billion dollars in the United States and 3.6 billion dollars worldwide. Currently, refrigerated air is the most widely used means of cooling datacenter’s servers. Modern datacent ...
In two-phase systems there are many singularities in piping systems, one of which in particular are U-bends (also called 180 degrees return bends or U-tubes) found very often in air conditioning coils, refrigerant systems, etc. Contrary to the literature c ...
Thermal designers of data centers and server manufacturers are showing a greater concern regarding the cooling of the new generation data centers, which consume considerably more electricity and dissipate much more waste heat, a situation that is creating ...
This study investigates the potential for energy and water sustainability in hot and humid climates by utilizing the condensate captured from large dedicated air handling units (AHUs) for pre-cooling outdoor air in another AHU and subsequently offsetting c ...
Thermal designers of data centers and server manufacturers are showing a great concern regarding the cooling of new generation data centers, which are more compact and dissipate more power than is currently possible to cool by conventional air conditioning ...
Measurements ith tracer gases were performed, together with more classical temperature and air velocity measurements, on various ventilation systems installed in the test chamber of Sulzer Infra, in Winterthur. The test chamber was arranged to simulate an ...
In tropical and subtropical regions, air-conditioning is employed throughout the year, which poses a significant challenge to the designer in reducing its energy consumption. Buildings in these regions would have latent load that is large enough throughout ...