Cryo-EM structure of the extended type VI secretion system sheath-tube complex
Graph Chatbot
Chat with Graph Search
Ask any question about EPFL courses, lectures, exercises, research, news, etc. or try the example questions below.
DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.
The response of Y2O3 nanoprecipitates in a 1-mu m YBa2Cu3O7-x layer from a superconducting wire Ag/YBCO/buffer metal oxides/Hastelloy to 107 MeV Kr and 167 MeV Xe ion irradiation was investigated using a combination of transmission electron microscopy, dif ...
Recently, single-particle cryo-electron microscopy emerged as a technique capable of determining protein structures at near-atomic resolution and resolving protein dynamics with a temporal resolution ranging from second to milliseconds. This thesis describ ...
Observing the fast dynamics of nanoscale systems is crucial in order to understand and ultimately control their behavior. Characterizing these dynamic processes requires techniques with atomic spatial resolution and a temporal resolution that matches the t ...
Transmission electron microscopy (TEM) offers an ample range of complementary techniques which are able to provide essential information about the physical, chemical and structural properties of materials at the atomic scale, and hence makes a vast impact ...
We present a new software package called Focus that interfaces cryo-transmission electron microscopy (cryo-EM) data collection with computer image processing. Focus creates a user-friendly environment to import and manage data recorded by direct electron d ...
Electron microscopy (EM) entered a new era with the emergence of direct electron detectors and new nanocrystal electron diffraction methods. However, sample preparation techniques have not progressed and still suffer from extensive blotting steps leading t ...
Contractile injection systems (bacteriophage tails, type VI secretions system, R-type pyocins, etc.) utilize a rigid tube/contractile sheath assembly for breaching the envelope of bacterial and eukaryotic cells. Among contractile injection systems, bacteri ...
We present a sample preparation method for cryo-electron microscopy (cryo-EM) that requires only 320 nL of sample to prepare a cryo-EM grid, depending on the protocol used. The sample is applied and spread on the grid by a microcapillary. The procedure doe ...
This review compares and discusses conventional versus miniaturized specimen preparation methods for transmission electron microscopy (TEM). The progress brought by direct electron detector cameras, software developments and automation have transformed tra ...
Variations of Vickers hardness were observed in Al-Mg-Mn alloy and Al-Mg-Mn-Sc-Zr alloy at different ageing times, ranging from a peak value of 81.2 HV at 54 ks down to 67.4 HV at 360 ks, below the initial hardness value, 71.8 HV at 0 ks for the case of Al ...