Online Aerosol Chemical Characterization by Extractive Electrospray Ionization-Ultrahigh-Resolution Mass Spectrometry (EESI-Orbitrap)
Graph Chatbot
Chat with Graph Search
Ask any question about EPFL courses, lectures, exercises, research, news, etc. or try the example questions below.
DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.
A range of coordination and organometallic compounds have been analysed by quadrupole ion-trap mass spectrometry using various photoionisation methods. Atmospheric-pressure photo ionisation (APPI), which combines atmospheric-pressure chemical ionisation (A ...
Effects of nanosecond electromagnetic pulses on metallic (Al) and semiconductor (Si, GaAs) surfaces were investigated exptl. in vacuum. For the surface c.d. 104-106 Wcm-2, an impulse desorption of ions was obsd. from adsorbed gaseous layers or deposited or ...
We report on a novel gas spectrometry technique using pyroelectric thin-him arrays. The 1 x 50 element arrays of PZT are integrated onto silicon using a membrane structure. The experimental characterization of the pyroelectric elements shows both high volt ...
This study explores the potential of MALDI-TOF MS for the mass measurement of large non-covalent protein complexes. The following non-covalent complexes have been investigated: aerolysin from Aeromonas hydrophila (335 kDa) and α-haemolysin from Staphylococ ...
Ion traps are an increasingly common presence as mass analysers in commercial bench-top mass spectrometers. Such instruments, usually interfaced with electrospray ionisation or nanospray sources, are invariably aimed at organic and biological applications, ...
It is well known in secondary ion mass spectrometry (SIMS) that sample topography leads to decreased mass resolution. Specifically, the ion's time of flight is dependent on where it was generated. Here, using matrix-enhanced SIMS, it is demonstrated that, ...
Attachment-induced ionization instability has been experimentally observed in O-2 and CF4 capacitive RF discharges using time-resolved voltage probe, Langmuir probe, optical emission and mass spectrometry measurements. This instability occurs under specifi ...
The recently developed technique of energy‐dependent electrospray ionisation mass spectrometry (EDESI‐MS) has been implemented on a triple quadrupole mass spectrometer such that fragmentation occurs in the collision cell rather than at the skimmer cone. Th ...
A review, with 9 refs., is given on trace element anal. by mass spectrometry (MS) and potentiometric stripping anal. (PSA). The key question of the problem is detn. of the structure of the samples (i.e. distribution functions and concns. of atoms, mols., c ...
"Thermal desorption experiments" were carried out during which heavy metal evaporation was studied by on-line monitoring. This could be achieved by the use of a tubular furnace connected to a heavy metal detector, i.e. an ICP-OES (inductively coupled plasm ...