Publication

Reversible solid-oxide cell stack based power-to-x-to-power systems: Comparison of thermodynamic performance

Abstract

The increasing penetration of variable renewable energies poses new challenges for grid management. The economic feasibility of grid-balancing plants may be limited by low annual operating hours if they work either only for power generation or only for power storage. This issue might be addressed by a dual-function power plant with power-to-x capability, which can produce electricity or store excess renewable electricity into chemicals at different periods. Such a plant can be uniquely enabled by a solid-oxide cell stack, which can switch between fuel cell and electrolysis with the same stack. This paper investigates the optimal conceptual design of this type of plant, represented by power-to-x-to-power process chains with x being hydrogen, syngas, methane, methanol and ammonia, concerning the efficiency (on a lower heating value) and power densities. The results show that an increase in current density leads to an increased oxygen flow rate and a decreased reactant utilization at the stack level for its thermal management, and an increased power density and a decreased efficiency at the system level. The power-generation efficiency is ranked as methane (65.9%), methanol (60.2%), ammonia (58.2%), hydrogen (58.3%), syngas (53.3%) at 0.4 A/cm2, due to the benefit of heat-to-chemical-energy conversion by chemical reformulating and the deterioration of electrochemical performance by the dilution of hydrogen. The power-storage efficiency is ranked as syngas (80%), hydrogen (74%), methane (72%), methanol (68%), ammonia (66%) at 0.7 A/cm2, mainly due to the benefit of co-electrolysis and the chemical energy loss occurring in the chemical synthesis reactions. The lost chemical energy improves plant-wise heat integration and compensates for its adverse effect on power-storage efficiency. Combining these efficiency numbers of the two modes results in a rank of round-trip efficiency: methane (47.5%) > syngas (43.3%) ≈ hydrogen (42.6%) > methanol (40.7%) > ammonia (38.6%). The pool of plant designs obtained lays the basis for the optimal deployment of this balancing technology for specific applications.

About this result
This page is automatically generated and may contain information that is not correct, complete, up-to-date, or relevant to your search query. The same applies to every other page on this website. Please make sure to verify the information with EPFL's official sources.
Related concepts

Loading

Related publications

Loading