The drawbacks of conventional Modular Multilevel Converters (MMC) are described in terms of short-circuits. The configuration of MMC-transformer-MMC proves to handle short-circuits at the input and output without the need for additional DC or AC circuit br ...
The major drawback for the commercialization of fault current limiter (FCL) made of YBCO on sapphire is their expensive price. In the recent years, coated conductors (CC) have been extensively developed and, due to their lower prices, have been recently te ...
Institute of Electrical and Electronics Engineers2009
This paper presents a preliminary work on a resonant circuit, also called AC-dipole. The resonance frequency of the circuit is changed by the mean of a variable capacitor connecting an inductor. For this purpose, a bank of switched capacitors of different ...
Ieee Service Center, 445 Hoes Lane, Po Box 1331, Piscataway, Nj 08855-1331 Usa2009
Power Factor Corrected rectifiers are a new tendency in development of power supplies. In the last few years, a lot of R&D activities have led to a new category of products for one-phase applications. In this contribution, a new simplified topology is prop ...
Geometrical aspects of the design of fault current limiters (FCL) have a great impact on their performance. Recently, the University of Geneva have presented optimized geometries obtained by splitting the FCL into many small dissipative lengths in order to ...
A new test facility, dedicated to the measurement of contact resistance distribution in full-size conductor termination, has been designed and manufactured at CRPP Fusion Technology in Villigen, Switzerland. The facility will be used to characterize and qu ...
Power-electronic inverters are becoming popular for various industrial drives applications. In recent years also high-power and medium-voltage drive applications have been installed. However, the existing solutions suffer from some important drawbacks. Hyb ...
Transient stability investigations consist of studying the rotor oscillations of generators (electro-mechanic oscillations, 0.1-2 Hz) after the occurrence of a fault of large amplitude, e.g. short circuit. The goal is to indicate if the generators are capa ...
1999
Graph Chatbot
Chat with Graph Search
Ask any question about EPFL courses, lectures, exercises, research, news, etc. or try the example questions below.
DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.
Three subsize NbTi cable-in-conduit conductors have been tested in SULTAN test facility. The conductors are identical in the cable layout but they are different in transverse resistance: either SnAg strand coating without wraps, or Ni strand coating withou ...
The adjunction of constrictions along the meander of a superconducting Fault Current Limiter (FCL) greatly improves its behavior thanks to a better distribution of the dissipative zones at the occurrence of a short circuit. This design works perfectly for ...