DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.
Five subsize NbTi cable-in-conduit conductors with parametric variations were fabricated and their DC performance was tested in the SULTAN facility. A comparison of the measured strand data and the cable performances clearly indicates that the current carr ...
OPTIMIZATION OF A SEMI-BATCH REACTION SYSTEM UNDER SAFETY CONSTRAINTS O. Ubrich+, B. Srinivasan*, F. Stoessel+, D. Bonvin* * Novartis Services AG, CH-4002 Basel, Switzerland Institut d’ utomatique, Ecole Polytechnique Fédérale de Lausanne A CH-1015, Lausan ...
The magnetic field in a coil results in a transverse force on the strands pushing the cable towards one side of the jacket. A special cryogenic press has been built to study in a unique way the mechanical and electrical properties of full-size ITER Cable-i ...
The summer of 2003 was extremely hot in Western Europe and in the Alps. Here I analyse the role of elevation in the temperatures measured in 2003, and I compare daytime and nighttime values. Records from 16 stations at varying elevations show that, during ...
The conceptual design of the large gap Spectrometer Dipole for the LHC-b experiment is presented here. The required acceptance implies a gap height of 3.6 m and a width of 4.3 m. Although the magnetic induction of the 1.92 m long magnet is only 1.1 T, it t ...
The design of a binary superconducting 1 kA current lead, operating between 300 K and 4.2 K, will be presented. The normal conducting part of the lead, will be cooled by high pressure helium gas of 60 K inlet temperature. The resulting warm end temperature ...
A modified bench scale calorimeter has been employed to det. the heat generated by various microbial strains growing on a range of different substrates, covering degrees of redn. from 3 to 6.13. The results are analyzed and interpreted in the light of coup ...
Following the pioneering work of the AGS Tokyo half project, a geographical information system has been developed to model the energy requirement of a urban area. The purpose of this platform is to model with sufficient details the energy services requirem ...