Seismic Testing of Adjacent Interacting Masonry Structures – Analysis of a Blind Prediction
Graph Chatbot
Chat with Graph Search
Ask any question about EPFL courses, lectures, exercises, research, news, etc. or try the example questions below.
DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.
U-shaped or channel-shaped walls are frequently used as lateral strength providing members in reinforced concrete (RC) buildings since their form does not only provide strength and stiffness in any horizontal direction but is also well suited to accommodat ...
With the introduction of higher seismic design forces in the Swiss loading standard of 2003 most unreinforced masonry (URM) buildings failed to satisfy the seismic design check. For this reason, in new construction projects, a number of URM walls are nowad ...
Due to daylight variability, a design cannot be thoroughly assessed using single-moment simulations, which is why we need dynamic performance metrics like Daylight Autonomy and Useful Daylight Illuminance. Going one step further, the annual variation in pe ...
When testing multi-storey structures, most testing facilities require the testing of a reduced-scale model. A literature review on tests of scaled masonry structural components revealed that scaling of masonry was rather challenging and often significant d ...
In Switzerland many new residential buildings are constructed as unreinforced masonry (URM) structures or as mixed structures where URM walls are coupled with reinforced concrete (RC) walls by RC slabs. At present the boundary conditions of URM walls subje ...
Unreinforced masonry (URM) structures are known to be rather vulnerable to seismic loading. Modern URM buildings with reinforced concrete (RC) slabs might, however, have an acceptable seismic performance for regions of low to moderate seismicity. In partic ...
For a shake table test on a four-storey structure with both unreinforced hollow-core brick masonry (URM) walls and reinforced concrete (RC) walls, the test unit had to be constructed at half-scale. While past experience showed that testing RC structural el ...
We present a damage scenario based on multidisciplinary study which covers the key elements of the earthquake risk chain in Visp. Full dynamic rupture simulations are performed using heterogeneous initial distributions, statistically compatible to the data ...
This work presents a method for estimating the expected damage caused by an earthquake on steel buildings in Puerto Rico. Since Puerto Rico is located between a series of tectonic faults, buildings could suffer the damages caused by a major earthquake. The ...
Existing unreinforced masonry (URM) buildings, many of which have historical and cultural importance, constitute a significant portion of existing buildings around the world. Recent earthquakes have shown the vulnerability of such URM buildings. This thesi ...