DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.
The capacities of performance improvements of low and mid-size heat pumps are studied in this project. For the new buildings market, the components of the heat pump match already well the requirements for high performance and monovalent heating. Minor impr ...
This project is evaluating a heat pump cycle with midstage injection at scroll compressors. The injected refrigerant is evaporated partially by an internal heat exchanger (fig. 2.1). A glycol-water heat pump with 12 kW heat capacity at B-5/W50 was built an ...
A complex heating and cogeneration plant including two 3.9 MWth ammonia heat pumps and two 3 MWel gas turbines with heat recovery boilers and three storage tanks of 66 GJ has been in operation since 1986. The heating surface is actually about 280’000 m2 an ...
In this report different air-water heat pump cycles under the operating conditions of the retrofit market and in the low heating power range are examined. The already existing heat pump models show excessive power and efficiency loss at very low ambient te ...
Targeting the integration of the utility system in an industrial site, introduces the problem of combined heat and power production and more specifically the optimal integration of the steam network. We present a mathemat ical tool that allows, using only ...
The pinch analysis method is a useful tool for the energy integration of industrial processes (structuring and simplification using simple guidelines). The pinch analysis method, extended to include exergy factors, falls within the framework of a global mu ...
The industrial conversion to new alternative refrigerants is now one of the major driving forces in two-phase flow and boiling heat transfer research. A state-of- the-art review is presented here to quantify what has been done so far, assess the strengths ...
Intube evaporation tests for R-407C and R-407C/oil are reported for a plain copper tube. The tests were run at a nominal inlet pressure of 6.45 bar (93.5 psia) at mass velocities of 100, 200 and 300 kg/m2s (73581, 147162 and 220743 lb/h ft2) over nearly th ...
Replacing conventional boilers by air to water heat pumps represents a major market opportunity and a contribution to more sustainable heating approaches. However, such retrofit situation impose tough technical requirements which must be met in order to de ...
The substitution of CFC refrigerants in refrigeration systems, heat pumps and organic Rankine cycles for heat recovery, requires good methods for predicting heat transfer of substitute fluids. The measurements in the LENI test facility (concentric tubes wi ...