Isolation of selected exchange processes in nuclear magnetic resonance
Graph Chatbot
Chat with Graph Search
Ask any question about EPFL courses, lectures, exercises, research, news, etc. or try the example questions below.
DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.
The abatement of organic micropollutants during oxidation processes has become an emerging issue for various urban water systems such as drinking water, wastewater, and water reuse. Reaction kinetics and mechanisms play an important role in terms of effici ...
In this study, the mechanism and kinetics of C3H8 dehydrogenation and cracking are examined over Ga/H-MFI catalysts prepared via vapor-phase exchange of H-MFI with GaCl3. The present study demonstrates that GaH cations are the active centers for C3H8 ...
Extent-based kinetic identification is a modeling technique that uses number of moles / concentrations measurements to compute extents and identify reaction kinetics (partial orders of reactions and reaction rate constant) by the integral method of paramet ...
We present a new fast real time and quantitative gas analysis method by means of mass spectrometry (MS), which has approximately an order of magnitude faster sampling rate in comparison with a traditional gas chromatography. The method is presented and dis ...
Nuclear magnetic resonance (NMR) spectroscopy is one of the most powerful and informative methods to probe molecular dynamics. Specifically, chemical exchange is an important phenomenon and one of the earliest and most vigorously investigated in NMR spectr ...
Complexes of lanthanide (III) ions have been used in structural studies of biomolecules and as contrast agents (CA). Clinically approved CAs have only one water molecule in their first coordination sphere. Structure and water exchange rate of these complex ...
Water exchange kinetics on [Ln(AAZTAPh–NO2)(H2O)q]− (Ln = Gd3+, Dy3+, or Tm3+) were determined by 1H nuclear magnetic resonance (NMR) measurements. The number of inner-sphere water molecules was found to change from two to one when going from Dy3+ to Tm3+. ...
Diamond magnetometry is a quantum sensing method involving detection of magnetic resonances with nanoscale resolution. For instance, T1 relaxation measurements, inspired by equivalent concepts in magnetic resonance imaging (MRI), provide a signal that is e ...
Water exchange kinetics of [Ln(L)(H2O)2]x complexes (Ln = Pr, Nd, Dy, Tm, and Yb; L = DO3A and DTTA–Me) were studied by 17O NMR spectroscopy as a function of temperature, pressure, and frequency and by 1H nuclear magnetic relaxation dispersion. Water excha ...
Hyperpolarized γ-Glu-[1-13C]Gly provides a non-invasive means to detect γ-glutamyl transpeptidase (GGT) enzyme activity in vivo with potential for application in functional imaging. Since GGT is most abundant in the proximal tubules of the kidney, and sinc ...