Abstract

In order to develop the new generation of motor pump (water) for heating or for cooling applications, a structural motor study was made to determine the best motor corresponding to the specifications. Stator structures, winding, supplying mode, pole number, etc. are the parameters of this study. To analyse them, several software packages were developed in order to design each solution as best as possible. This paper first describes the differences between the choice of the motor based on the phase number and the supply (uni or bi-directional). Secondly, the influence and the choice of the back-EMF shape versus supplying mode is analysed. Finally, the motor design comparison is presented showing the advantages and disadvantages of each solution

About this result
This page is automatically generated and may contain information that is not correct, complete, up-to-date, or relevant to your search query. The same applies to every other page on this website. Please make sure to verify the information with EPFL's official sources.

Graph Chatbot

Chat with Graph Search

Ask any question about EPFL courses, lectures, exercises, research, news, etc. or try the example questions below.

DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.