A new approach to accurate measurement of uniaxial joint angles based on a combination of accelerometers and gyroscopes
Related publications (33)
Graph Chatbot
Chat with Graph Search
Ask any question about EPFL courses, lectures, exercises, research, news, etc. or try the example questions below.
DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.
Nowadays inertial sensors are extensively used for gait analysis. They can be used to perform temporal event detection (i.e. step detection) and to estimate the orientation of the feet and other body segments to determine walking speed and distance. Usuall ...
Functional calibration methods were devised to improve repeatability and accuracy of the knee flexion-extension axis, which is used to define the medio-lateral axis of the femur coordinate system in gait analysis. Repeatability of functional calibration me ...
Background: Although the importance of accurate femoral reconstruction to achieve a good functional outcome is well documented, quantitative data on the effects of a displacement of the femoral center of rotation on moment arms are scarce. The purpose of t ...
In this work we present the implantable and wearable measurement system developed for smart knee prostheses monitoring. The kinematic measurement system contains three anisotropic magnetoresistive sensors embedded into the polyethylene part of the prosthes ...
Gait analysis methods to estimate spatiotemporal measures, based on two, three or four gyroscopes attached on lower limbs have been discussed in the literature. The most common approach to reduce the number of sensing units is to simplify the underlying bi ...
Institute of Electrical and Electronics Engineers2013
, , ,
In this work, we studied a combination of embedded magnetic measurement system in a knee prosthesis and wearable inertial sensors to estimate two knee joint rotations namely flexion-extension and internal-external rotations. The near optimal sensor configu ...
2013
,
To obtain valid 3D joint angles with inertial sensors careful sensor-to-segment calibration (i.e. functional or anatomical calibration) is required and measured angular velocity at each sensor needs to be integrated to obtain segment and joint orientation ...
Public Library of Science2017
,
We investigated how the visual system selects a reference frame for the perception of motion. Two concentric arcs underwent circular motion around the center of the display, where observers fixated. The outer (target) arc's angular velocity profile was mod ...
Association for Research in Vision and Ophthalmology (ARVO)2016
The retinotopic projection of stimulus motion depends both on the motion of the stimulus and the movements of the observer. In this study, we aimed to quantify the contributions of endogenous (retinotopic) and exogenous (spatiotopic and motion-based) refer ...
Elsevier2015
, ,
A new method for the estimation of ego-motion (the direction and amplitude of the velocity) of a mobile device comprising optic-flow and inertial sensors (hereinafter the apparatus). The velocity is expressed in the apparatus's reference frame, which is mo ...