In electrical engineering, the power gain of an electrical network is the ratio of an output power to an input power. Unlike other signal gains, such as voltage and current gain, "power gain" may be ambiguous as the meaning of terms "input power" and "output power" is not always clear. Three important power gains are operating power gain, transducer power gain and available power gain. Note that all these definitions of power gains employ the use of average (as opposed to instantaneous) power quantities and therefore the term "average" is often suppressed, which can be confusing at occasions. The operating power gain of a two-port network, GP, is defined as: where PL is the maximum time-averaged power delivered to the load, where the maximization is over the load impedance, i.e., we desire the load impedance which maximizes the time-averaged power delivered to the load. PI is the time-averaged input power to the network. If the time-averaged input power depends on the load impedance, one must take the maximum of the ratio, not just the maximum of the numerator. The transducer power gain of a two-port network, GT, is defined as: where PL is the average power delivered to the load PS max is the maximum available average power at the source In terms of y-parameters this definition can be used to derive: where YL is the load admittance YS is the source admittance This result can be generalized to z, h, g and y-parameters as: where kxx is a z, h, g or y-parameter ML is the load value in the corresponding parameter set MS is the source value in the corresponding parameter set PS max may only be obtained from the source when the load impedance connected to it (i.e. the equivalent input impedance of the two-port network) is the complex conjugate of the source impedance, a consequence of the maximum power theorem. The available power gain of a two-port network, GA, is defined as: where PL max is the maximum available average power at the load PS max is the maximum power available from the source Similarly PL max may only be obtained when the load impedance is the complex conjugate of the output impedance of the network.

À propos de ce résultat
Cette page est générée automatiquement et peut contenir des informations qui ne sont pas correctes, complètes, à jour ou pertinentes par rapport à votre recherche. Il en va de même pour toutes les autres pages de ce site. Veillez à vérifier les informations auprès des sources officielles de l'EPFL.

Graph Chatbot

Chattez avec Graph Search

Posez n’importe quelle question sur les cours, conférences, exercices, recherches, actualités, etc. de l’EPFL ou essayez les exemples de questions ci-dessous.

AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.