AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.
In two-stage solid-state transformers with input-series output-parallel structure, the LLC converter operating at a fixed switching frequency is a common choice for the isolated DC/DC conversion stage because it can provide a high efficiency and a fixed vo ...
Solid-State Transformers with Input-Series/Output-Parallel configuration offer a convenient solution for AC/DC conversion due to their scalability and modularity. In this configuration, each module experiences a second-order harmonic ripple caused by local ...
Solid-State Transformers with Input-Series/Output- Parallel configuration offer a convenient solution for AC/DC power conversion, thanks to their modularity, scalability and flexibility. However, as known, they are affected by a second-order harmonic rippl ...
In this paper, we analyze the integration of small antennas in a drone protected by a conductive structure. They must be light and resistant to provide high collision resilience, which is critical for drones flown indoors and in complex environments. To ac ...
In spite of the dominance of ac technology for the vast majority of power transmission and distributionsince the late 19th century, the past decades have seen an increase in use of dc electrical power. Inparticular, this has been the case both in high volt ...
The present invention relates to a DC/DC converter (1) for transferring an active power between two DC subsystems (5, 6) comprising: - a first converter stage (3) and a second converter stage (4) both configured to be selectively operated as an active inve ...
This paper proposes a tower-foot grounding system model compatible with EMT programs which might be useful for the simulation of lightning transients in overhead lines. The proposed model is based on the solution of the telegrapher's equations and the appl ...
In this paper, a rigorous and independent validation of two different approaches for calculating the ground-return impedance and admittance of multiconductor underground cable systems using the transmission line theory is carried out. Furthermore, analyses ...
Owing to the advancements in the area of power electronics, efficient and flexible ac to dc conversion is made possible, bringing back into focus the idea of the dc power transmission at various voltage levels. Several technical and economical factors advo ...
The Tokamak a` Configuration Variable (TCV) coil converters are fed, during the plasma pulse, by a flywheel generator (FG) providing the AC voltages few seconds before the plasma pulse. The synchronization with the 120 Hz frequency delivered by the FG, var ...