Posez n’importe quelle question sur les cours, conférences, exercices, recherches, actualités, etc. de l’EPFL ou essayez les exemples de questions ci-dessous.
AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.
On many tokamaks the reconstruction of the magnetic field structure in the plasma is supported by polarimetric measurements. Recent proposed and realized methods are based on a far-infrared laser beam with a rotating polarization ellipse. The same instrume ...
The Brillouin fibre laser has experimentally demonstrated its suitability for the measurement of laser linewidth in the 1 kHz to 500 kHz frequency range. A major advantage of this system is to be widely independent of the source wavelength by generating th ...
Microgun-pumped blue lasers with lasing thresholds in the 4-20 kW/cm(2) range for temperatures between 83 and 225 K were fabricated by molecular beam epitaxy. The devices exploit graded index, separate confinement Zn1-xCdxSe/ZnSe heterostructures and use a ...
Single-pass Raman cells pumped by either a quadrupled Nd:YAG (266-nm) laser or a KrF excimer laser are studied. The Raman-active gases comprise H2, D2, or CH4, as well as a mixt. of them, with the addn. of He, Ne, or Ar. A parametric study, in which the St ...
On-column thermooptical absorbance (TOA) detection in capillary electrophoretic separations of various nucleoside and mono- and diphosphate nucleotide mixtures absorbing at 257 nm is demonstrated in 20 μm i.d. capillaries. The analytes are optically pumped ...
A novel configuration of a distributed fiber sensor by Brillouin gain analysis has been developed for temperature and strain monitoring. It uses a single laser source, and the required light signals are all generated with an electro-optic modulator, result ...
Strained In0.35Ga0.65As/GaAs quantum wells of various thicknesses (6-16 monolayers) obtained by molecular beam epitaxy at 400 degrees C were studied by optical pumping techniques at 4 K. Improved quantum well optical properties, due to significant increase ...
The biomedical use of an optical fiber-based spectro- temporal fluorometer that can endoscopically record the fluorescence decay of an entire spectrum without scanning is presented. The detector consists of a streak camera coupled to a spectrograph. A mode ...
The present work is part of a feasibility study to investigate the excimer laser photon-assisted thermal decompn. of anthracene at 248 nm. The principle is to combine UV photons of an appropriate light source and heat in an incinerating reactor at modest t ...
This device for measuring Brillouin scattering includes a single laser source (11), a modulator (12) placed on the path of the light emitted by the source (11) and designed to generate a pumping signal and a test signal which are injected to one end (13) o ...