In architecture, a daylight factor (DF) is the ratio of the light level inside a structure to the light level outside the structure. It is defined as: DF = (Ei / Eo) x 100% where, Ei = illuminance due to daylight at a point on the indoors working plane, Eo = simultaneous outdoor illuminance on a horizontal plane from an unobstructed hemisphere of overcast sky. To calculate Ei, requires knowing the amount of outside light received inside of a building. Light can reach a room via through a glazed window, rooflight, or other aperture via three paths: Direct light from a patch of sky visible at the point considered, known as the sky component (SC), Light reflected from an exterior surface and then reaching the point considered, known as the externally reflected component (ERC), Light entering through the window but reaching the point only after reflection from an internal surface, known as the internally reflected component (IRC). The sum of the three components gives the illuminance level (typically measured in lux) at the point considered: Illuminance = SC + ERC + IRC The daylight factor can be improved by increasing SC (for example placing a window so it "sees" more of the sky rather than adjacent buildings), increasing ERC (for example by painting surrounding buildings white), increasing IRC (for example by using light colours for room surfaces). In most rooms, the ceiling and floor are a fixed colour, and much of the walls are covered by furnishings. This gives less flexibility in changing the daylight factor by using different wall colours than might be expected meaning changing SC is often the key to good daylight design. Architects and engineers use daylight factors in architecture and building design to assess the internal natural lighting levels as perceived on working planes or surfaces. They use this information to determine if light is sufficient for occupants to carry out normal activities. The design day for daylight factor calculations is based on the standard CIE overcast Sky for 21 September at 12:00pm, and where the Ground Ambient light level is 11921 Lux.

À propos de ce résultat
Cette page est générée automatiquement et peut contenir des informations qui ne sont pas correctes, complètes, à jour ou pertinentes par rapport à votre recherche. Il en va de même pour toutes les autres pages de ce site. Veillez à vérifier les informations auprès des sources officielles de l'EPFL.

Graph Chatbot

Chattez avec Graph Search

Posez n’importe quelle question sur les cours, conférences, exercices, recherches, actualités, etc. de l’EPFL ou essayez les exemples de questions ci-dessous.

AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.