Protection of tapped transmission lines with grounded neutrals has been always a challenging problem, usually resulting in compromise solutions. This type of lines may be protected by pilot relaying requiring dedicated and reliable telecommunication links. ...
High-temperature superconductors (HTS) can be superconducting in liquid nitrogen (77 K) at atmospheric pressure, which holds immense promises for our future such as nuclear fusion, compact medical devices and efficient power applications. In a power system ...
This paper presents demonstration of a protection scheme integrated into marine DC power distribution networks to investigate the coordination between each protection action. The integrated protection scheme is based on three different time-frame protectio ...
Winged drones that fly in close proximity to obstacles or that are capable of aerial and terrestrial locomotion can benefit from protective systems that prevent damage to delicate aerial structures. Existing protective solutions focus on multi-copter drone ...
Recent trends in shipboard power distribution network design, such as the transition from AC to DC result in new challenges on the issue of distribution network protection. Devices such as a solid state bus tie switch provide a first line of defence agains ...
The deexcitation of a synchronous machine has been used for the protection of the power supply based on a diode rectifier in marine dc power distribution networks. The fault current from the generator can be eliminated with the protection method utilizing ...
Hybrid modular multilevel converter control and design for pumped hydro storage plants is presented, addressing application-specific shortcoming of conventional back-to-back half-bridge modular multilevel converter: high common-mode-voltage machine stress. ...
The increasing penetration of renewable energy sources, energy storage systems (ESSs), and DC loads has opened the door to DC technology to pave its way into future grids. The shift has been more obvious in the marine domain supported by track records of i ...
The extensive deployment of non-synchronous generation determines lower level of grid inertia resulting in deteriorated frequency containment performance and abnormal frequency excursions in case of contingency. This calls for identifying assets, controls, ...
DC shipboard power systems have been connsidered as a promising solution for stricter environmental regulations on ships due to their main benefits in fuel savings with variable speed engines and easy integration of energy storage systems. In order to empl ...