Posez n’importe quelle question sur les cours, conférences, exercices, recherches, actualités, etc. de l’EPFL ou essayez les exemples de questions ci-dessous.
AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.
Well-designed ventilated air-spaces behind external claddings in the building envelope can potentially reduce thermal energy flow in the entire wall structure. In this study, the impact of the dynamic thermo-hydraulic behavior of the flow in the naturally ...
The goal of this project was to work on room occupancy and to provide solutions and ideas on how to detect if a room is occupied or not using generic and non expensive sensors. This is motivated by the fact that buildings account for 50% of the total energ ...
One of the primary driving factors in building energy performance is occupant behavioral dynamics. As a result, the layout of building occupant workstations is likely to influence energy consumption. In this paper, we introduce methods for relating lightin ...
We performed the first large-scale investigation of indoor air quality (IAQ), energy and occupant behavior and satisfaction, in 650 energy-efficient dwellings in western Switzerland. The investigation included comparative assessment of 217 green-certified ...
Building energy codes have been implemented in Switzerland as well as across the world to reduce building energy consumption, however, due to the progressive effect of climate change phenomena and the precipitate change in occupancy patterns due to the glo ...
Coronavirus disease 2019 (COVID-19) has caused strain on health systems worldwide due to its high mortality rate and the large portion of cases requiring critical care and mechanical ventilation. During these uncertain times, public health decision makers, ...
The amount of heat flux passing through the building envelope directly affects the energy use for the thermal conditioning of the building. The ventilated cavity behind the traditional external claddings (e.g., vinyl siding, brick veneer) adjacent to the w ...
AMER SOC HEATING, REFRIGERATING AND AIR-CONDITIONING ENGS2021
Mechanical ventilation can damage the lungs, a condition called Ventilator-Induced Lung Injury (VILI). However, the mechanisms leading to VILI at the microscopic scale remain poorly understood. Here we investigated the within-tidal dynamics of cyclic recru ...
We performed a post-occupancy assessment based on 500 occupant surveys in eight buildings using embedded radiant heating and cooling systems. This study follows-up on a quantitative assessment of 60 office buildings that found radiant and all-air buildings ...
For many decades, ventilated cavities in wall assemblies of buildings have been essential for creating moisture resilient constructions by allowing airflow within the air gap to promote drying. In addition to that, the airflow in the cavity can enhance the ...