Posez n’importe quelle question sur les cours, conférences, exercices, recherches, actualités, etc. de l’EPFL ou essayez les exemples de questions ci-dessous.
AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.
Global assessment of both cardiac and arterial function is important for a meaningful interpretation of pathophysiological changes in animal models of cardiovascular disease. We simultaneously acquired left ventricular (LV) and aortic pressure and LV volum ...
The peroxisome proliferator-activated receptor-alpha (PPARalpha) plays a major role in the control of cardiac energy metabolism. The role of PPARalpha on cardiac functions was evaluated by using PPARalpha knockout (PPARalpha -/-) mice. Hemodynamic paramete ...
For over a century, electrocardiology has been observing human cardiac activity through recordings of electrocardiograms (ECG). The potential differences derived from the nine electrodes of the standard 12-lead ECG, placed at their designated positions, ar ...
This paper explores a novel approach for ventricular and atrial activities estimation in electrocardiogram (ECG) signals, based on sparse source separation. Sparse decompositions of ECG over signal-adapted multi-component dictionaries can lead to natural s ...
The CSEM has developed an optomechanical linear scanner. This scanner has a limited displacement range, performed with high resolution. The resolution is obtained through a very high precision motion guiding of the scanner itself. This paper describes the ...
The CSE; has developed an optomechanical linear scanner. This scanner has a limited displacement range, performed with high resolution. The resolution is obtained through a very high precision motion guiding of the scanner itself. This paper describes the ...
The most common type of sustained arrhythmia is atrial fibrillation (AF), affecting about 2% of the general population and 8% to 11% of the elderly, more than 65 years of age. The treatment of atrial arrythmia is still based on empirical considerations and ...
This work reports on the design, fabrication, and characterization of CMOS pixels for subretinal implants, which seems to be an effective way to recover visual capabilities in some types of blindness. Two possible approaches are presented for CMOS pixel im ...
This report describes a patient with complex partial seizures arising from the right temporal lobe who developed symptomatic sinus arrest following the end of his seizure activity. A ventricular pacemaker was implanted and was documented to function approp ...
Purpose: To improve the quantification of myocardial perfusion by registering the time series of magnetic resonance (MR) images with injection of gadolinium. Materials and Methods: Eight patients underwent MR scans to perform myocardial perfusion exam. Two ...