Anton Kozhinov

Publications associées (19)

Adding Color to Mass Spectra of Biopolymers: Charge Determination Analysis (CHARDA) Assigns Charge State to Every Ion Peak

Yury Tsybin, Natalia Gasilova, Laure Menin, Anton Kozhinov, Konstantin Nagornov

Traditionally, mass spectrometry (MS) output is the ion abundance plotted versus the ionic mass-to-charge ratio m/z. While employing only commercially available equipment, Charge Determination Analysis (CHARDA) adds a third dimension to MS, estimating for ...
Amer Chemical Soc2024

Drug-to-Antibody Ratio Estimation via Proteoform Peak Integration in the Analysis of Antibody-Oligonucleotide Conjugates with Orbitrap Fourier Transform Mass Spectrometry

Yury Tsybin, Natalia Gasilova, Laure Menin, Anton Kozhinov, Konstantin Nagornov

The therapeutic efficacy and pharmacokinetics of antibody-drug conjugates (ADCs) in general, and antibody-oligonucleotide conjugates (AOCs) in particular, depend on the drug-to-antibody ratio (DAR) distribution and average value. The DAR is considered a cr ...
AMER CHEMICAL SOC2021

Transient-mediated simulations of FTMS isotopic distributions and mass spectra to guide experiment design and data analysis

Yury Tsybin, Natalia Gasilova, Laure Menin, Anton Kozhinov, Konstantin Nagornov

Fourier transform mass spectrometry (FTMS) applications require accurate analysis of extremely complex mixtures of species in a wide mass and charge state ranges. To optimize the related FTMS data analysis accuracy, parameters for data acquisition and the ...
2020

Multiplexed Middle-Down Mass Spectrometry as a Method for Revealing Light and Heavy Chain Connectivity in a Monoclonal Antibody

Yury Tsybin, Natalia Gasilova, Laure Menin, Anton Kozhinov, Konstantin Nagornov, Luca Fornelli, Kristina Srzentic, Daniel Ayoub

Pairing light and heavy chains in monoclonal antibodies (mAbs) using top-down (TD) or middle-down (MD) mass spectrometry (MS) may complement the sequence information on single chains provided by high-throughput genomic sequencing and bottom-up proteomics, ...
AMER CHEMICAL SOC2018

Device and Method for Ion Cyclotron Resonance Mass Spectrometry

Yury Tsybin, Anton Kozhinov, Konstantin Nagornov

The present invention relates to a method and device for measuring m/z ratios of ions in ion cyclotron resonance (ICR) mass spectrometry. The described ion traps for ICR mass spectrometry are distinct from the previous configurations by having one or many ...
2017

Fourier transform mass spectrometry at the uncertainty principle limit for improved qualitative and quantitative molecular analyses

Anton Kozhinov

Nowadays, among the instrumentation park of mass spectrometry, Fourier transform mass spectrometers (FTMS), including ion cyclotron resonance (ICR) and Orbitrap FTMS, provide the highest analytical performance for accurate measurements and mass resolution. ...
EPFL2015

Producing absorption mode Fourier transform ion cyclotron resonance mass spectra with non-quadratic phase correction functions

Yury Tsybin, Anton Kozhinov, Konstantin Nagornov, Konstantin Zhurov

RATIONALE: Previously described methods for producing absorption mode Fourier transform ion cyclotron resonance (FTICR) mass spectra have all relied on the phase correction function being quadratic. This assumption has been found to be invalid for some ins ...
Wiley-Blackwell2015

Ion Trap with Narrow Aperture Detection Electrodes for Fourier Transform Ion Cyclotron Resonance Mass Spectrometry

Yury Tsybin, Anton Kozhinov, Konstantin Nagornov

The current paradigm in ion trap (cell) design for Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) is the ion detection with wide aperture detection electrodes. Specifically, excitation and detection electrodes are typically 90A deg ...
Springer2015

Distinguishing analyte from noise components in mass spectra of complex samples: where to cut the noise?

Yury Tsybin, Anton Kozhinov, Luca Fornelli, Konstantin Zhurov

Fourier transform mass spectrometry (FTMS) enables comprehensive analysis of complex molecular mixtures. Given the broad intensity ranges of components in the mass spectra, it is imperative to accurately determine a noise threshold level above which peak a ...
Amer Chemical Soc2014

High-Resolution Fourier Transform Ion Cyclotron Resonance Mass Spectrometry with Increased Throughput for Biomolecular Analysis

Yury Tsybin, Anton Kozhinov, Konstantin Nagornov

A multielectrode ion cyclotron resonance (ICR) cell, herein referred to as the 4X cell, for signal detection at the quadruple frequency multiple was implemented and characterized on a commercial 10 T Fourier transform ICR mass spectrometer (FT-ICR MS). Not ...
Amer Chemical Soc2014

Graph Chatbot

Chattez avec Graph Search

Posez n’importe quelle question sur les cours, conférences, exercices, recherches, actualités, etc. de l’EPFL ou essayez les exemples de questions ci-dessous.

AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.