AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.
Current from nearby rocket-triggered lightning that flowed through the soil and into an unenergized test power distribution line was studied based on experimental data acquired in 2003 at the International Center for Lightning Research and Testing in Flori ...
A two-year experimental campaign on lightning-originated disturbances carried out in an Italian rural region characterized by a high ground flash density (4 flashes/km2/yr) has provided a set of voltage transient measurements in a medium voltage (MV) feede ...
The paper investigates the applicability of some closed form expressions for the ground impedance and ground admittance of buried horizontal wires (bare and insulated) for lightning or switching transient analyses based on transmission line (TL) theory. In ...
The paper deals with the subject of the source-identification of transient voltage disturbances in distribution system buses. In particular, a statistical procedure is proposed for the evaluation of the probability that a lightning flash detected by a Ligh ...
Monitoring units for the measurement of high frequencyvoltage transients have been in operation at three different busses of an Italian medium voltage (MV) distribution feeder, mainly composed by overhead lines, in March 2007 – August 2008. The feeder is l ...
The paper deals with the evaluation of the indirect-lightning performance of overhead distribution networks. The novelty of this contribution is that it takes into account the inherent complexity of distribution networks. These networks are indeed characte ...
The study of the interaction of lightning electromagnetic fields with electrical systems and the design of appropriate protection strategies are generally based on statistical distributions of the lightning current measured at the channel base using either ...
The paper deals with the correlation between lightning and distribution networks faults and/or voltage dips. In particular, the paper presents an application of a method proposed by the authors to correlate lightning events and relays operations based on t ...
This paper deals with the calculation of lightning-induced overvoltages on medium-voltage (MV) and low-voltage (LV) distribution networks taking into account the presence of MV-LV distribution transformers and, in particular, the surge transfer through the ...
The aim of this paper is to present the results of the performance study of medium voltage overhead distribution lines against lightning discharges, in the way to define methodologies to reduce the system failures. The results are obtained within the partn ...