Posez n’importe quelle question sur les cours, conférences, exercices, recherches, actualités, etc. de l’EPFL ou essayez les exemples de questions ci-dessous.
AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.
A record 730 nm parametric conversion in silica fiber from the near-infrared to the short-wave infrared band is reported and analyzed. A parametric gain in excess of 30 dB was measured for a signal at 1300 nm (with corresponding idler at 2030 nm). This con ...
The geometry of crescent-shaped noble-metal nanoparticles is systematically varied in terms of shape and size. The resulting changes in the plasmonic resonances of these structures are investigated by extinction spectroscopy revealing a rich polarization-d ...
Institute of Physics (IoP) and Deutsche Physikalische Gesellschaft2007
Photoacoustic spectroscopy is a widely recognised technique to measure trace gases at parts-per-million (ppm) or parts-per-billion (ppb) level using semiconductor laser in the near infrared range. This technique is based on the generation of an acoustic wa ...
Single frequency lasing from organic dye solutions on a monolithic poly(dimethylsiloxane) (PDMS) elastomer chip is demonstrated. The laser cavity consists of a single mode liquid core/PDMS cladding channel waveguide and a phase shifted 15th order distribut ...
Sensitive photoacoustic detection of methane (CH4), hydrogen chloride (HCI) and water vapour (H2O) in the near-infrared range using semiconductor DFB lasers is reported. A detection limit of 0.17 ppm of CH4, 0.2 ppm of HCI and 0.024 ppm of H2O (signal-to-n ...
We demonstrated a continuously tunable optofluidic distributed feedback (DFB) dye laser on a monolithic poly(dimethylsiloxane) (PDMS) elastomer chip. The optical feedback was provided by a phase-shifted higher order Bragg grating embedded in the liquid cor ...
Multi-hydrogenated compounds detection based on photoacoustic (PA) spectroscopy is reported. Three near-infrared semiconductor lasers are used with a resonant PA cell operated in its first longitudinal mode to monitor methane, water vapour and hydrogen chl ...
Spatial representativeness is an important quality criterion in trace gas monitoring, especially if measurements are intended for regulatory and model validation purposes. Open-path absorption spectroscopy techniques meet the representativeness requirement ...
We report direct absorption spectroscopic detection of ozone at ambient pressure with a pulsed, DFB quantum-cascade laser (QCL) tuned within 1044-1050 cm(-1) by temperature scanning. Wavelength calibration curves were derived from FTIR and CO2 spectra and ...
In recent years, optical gas detectors based on a tunable diode laser absorption spectrometer has become more and more important for monitoring trace gases in atmospheric, medical, and industrial processes. In the medical field, blood gases, essentially pO ...