AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.
Background Impaired heart rate variability (HRV) is associated with increased mortality in sinus rhythm. However, HRV has not been systematically assessed in patients with atrial fibrillation (AF). We hypothesized that parameters of HRV may be predictive o ...
Background: Consistently successful patient outcomes following catheter ablation (CA) for treatment of persistent atrial fibrillation (pers-AF) remain elusive. We propose an electrocardiogram (ECG) analysis designed to (1) refine selection of patients most ...
The sensing of left ventricular (LV) activity is fundamental in the diagnosis and monitoring of cardiovascular health in high-risk patients after cardiac surgery to achieve better short- and long-term outcome. Conventional approaches rely on noninvasive me ...
Aip Publishing2024
Atrial fibrillation (AF) is the most common cardiac arrhythmia; it will affect one in four adults worldwide in their lifetime. AF has serious consequences, including drastically increased risk of stroke. Catheter ablation surgery is an established treatmen ...
EPFL2023
, , , , , ,
In the last years, remote health monitoring is becoming an essential branch of health care with the rapid development of wearable sensors technology. To meet the demand of new more complex applications and ensuring adequate battery lifetime, wearable senso ...
In this thesis, we explore 3 main topics: non-uniform (in time) sub-sampling, QRS detection in an event-based sub-sampled ECG (electrocardiogram) and implementation on a low-power MCU (Micro Controller Unit). The main idea behind this work is to reduce the ...
2019
Photoplethysmography (PPG)-based monitoring devices will probably play a decisive role in healthcare environment of the future, which will be preventive, predictive, personalized and participatory. Indeed, this optical technology presents several practical ...
EPFL2018
Biomedical signal processing has become a very active domain of research nowadays. With the advent of portable monitoring devices, from accelerometer-enabled bracelets and smart-phones to more advanced vital sign tracking body area networks, this field has ...
EPFL2018
, , ,
Objectives The electrocardiogram (ECG) of patients with BrS in sinus rhythm might reflect intrinsic atrial electrical abnormalities independent from any previous atrial fibrillation (AF). Aim of this study is to investigate the presence of P-wave abnormali ...
Atrial Fibrillation (AF) is a type of cardiac arrhythmia that significantly increases the risk of stroke and heart failure. In general, in the case of patients affected by AF, their electrocardiogram (ECG) shows a typical pattern of irregular RR intervals ...