Size-Selective Diffusion in Nanoporous but Flexible Membranes for Glucose Sensors
Graph Chatbot
Chattez avec Graph Search
Posez n’importe quelle question sur les cours, conférences, exercices, recherches, actualités, etc. de l’EPFL ou essayez les exemples de questions ci-dessous.
AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.
We present a viscometric affinity biosensor that can potentially allow continuous multi-analyte monitoring in biological fluids like blood or plasma. The sensing principle is based on the detection of viscosity changes of a polymeric solution which has a s ...
Diabetes mellitus is a globally growing disease with more than 180 million cases worldwide and no cure exists. In order to minimize the many medical complications, tight glucose monitoring has been shown to be the best alternative. Many diabetics require i ...
To explore the real-time dynamic behavior of molecular transporters of the cell-penetrating-peptide (CPP) type on a biological membrane, single fluorescently labeled oligoarginine conjugates were imaged interacting with the plasma membrane of Chinese hamst ...
In order to realize an implantable glucose sensing system designed within this project, the realization of a selective nanoporous membrane is essential. The final goal of this sub-project is establishing a fabrication process of a semi-permeable membrane c ...
Maintaining the integrity of their protective plasma membrane is a primary requirement of cells. Accordingly, cellular events that breach the membrane are tightly regulated1. Artificial vesicles used in drug delivery must also stay intact until they have r ...
In this study, we examine the parameters that govern the overall oxygen flux through a permeation membrane. The chemical diffusion (D) and the surface exchange (k) coefficients for oxygen in La0.6Sr0.4Fe0.8Co0.2O3-d were determined as a function of tempera ...
For more than thirty years there has been a high demand for glucose measuring devices to replace the finger pricking methods and to improve the life quality of diabetics. Three approaches are possible, electrochemical, electromagnetic (including optical), ...
Details about molecular membrane dynamics in living cells, such as lipid-protein interactions, are often hidden from the observer because of the limited spatial resolution of conventional far-field optical microscopy. The superior spatial resolution of sti ...
Although a rigorous definition of growth-limiting substrate relies on a kinetic anal., a simple stoichiometric anal. based on the calcn. of the conversion is more applicable. Anal. of single and dual limitations is based on a simulated example for a substr ...
We present a viscometric affinity biosensor for continuous monitoring of glucose in biological fluids such as blood and plasma. The sensing principle of this chemico-mechanical sensor is based upon the viscosity variation of a sensitive fluid with glucose ...