Deviance information criterionThe deviance information criterion (DIC) is a hierarchical modeling generalization of the Akaike information criterion (AIC). It is particularly useful in Bayesian model selection problems where the posterior distributions of the models have been obtained by Markov chain Monte Carlo (MCMC) simulation. DIC is an asymptotic approximation as the sample size becomes large, like AIC. It is only valid when the posterior distribution is approximately multivariate normal.
Poulsvignette Le pouls est la perception du flux sanguin pulsé par le cœur par la palpation d'une artère. Le pouls fut étudié par plusieurs médecins antiques, dont Hippocrate de Cos, Hérodicos, Chrysermos, Héraclide d'Érythrées et Claude Galien. Il fut étudié avant cela en médecine chinoise. La prise de pouls consiste à appuyer avec les doigts, à travers la peau, une artère contre un os ; la pulpe des doigts permet de sentir les gonflements de l'artère dus à l'augmentation de la pression artérielle par la contraction du cœur (systole).
Paired difference testIn statistics, a paired difference test is a type of location test that is used when comparing two sets of paired measurements to assess whether their population means differ. A paired difference test uses additional information about the sample that is not present in an ordinary unpaired testing situation, either to increase the statistical power, or to reduce the effects of confounders.
Focused information criterionIn statistics, the focused information criterion (FIC) is a method for selecting the most appropriate model among a set of competitors for a given data set. Unlike most other model selection strategies, like the Akaike information criterion (AIC), the Bayesian information criterion (BIC) and the deviance information criterion (DIC), the FIC does not attempt to assess the overall fit of candidate models but focuses attention directly on the parameter of primary interest with the statistical analysis, say , for which competing models lead to different estimates, say for model .
Aortic ruptureAortic rupture is the rupture or breakage of the aorta, the largest artery in the body. Aortic rupture is a rare, extremely dangerous condition. The most common cause is an abdominal aortic aneurysm that has ruptured spontaneously. Aortic rupture is distinct from aortic dissection, which is a tear through the inner wall of the aorta that can block the flow of blood through the aorta to the heart or abdominal organs.
Oxygen windowIn diving and decompression, the oxygen window is the difference between the partial pressure of oxygen (PO2) in arterial blood and the PO2 in body tissues. It is caused by metabolic consumption of oxygen. The term "oxygen window" was first used by Albert R. Behnke in 1967. Behnke refers to early work by Momsen on "partial pressure vacancy" (PPV) where he used partial pressures of oxygen and helium as high as 2–3 ATA to create a maximal PPV.
Test des signesEn statistique, le test des signes est une alternative non-paramétrique au test T pour des échantillons appariés. La seule condition requise par ce test est que la distribution sous-jacente de la variable étudiée soit continue. Aucune condition sur la nature ou la forme de la distribution n'est requise. Le test est applicable lorsque l'on possède deux mesures de deux variables pour chaque individu et que l'on souhaite tester la significativité des différences entre les deux mesures.
Palier de décompressionthumb|Plongeurs lors d'un palier de décompression En plongée sous-marine, un palier de décompression est le temps que l'on passe à une profondeur donnée afin de réduire le taux d'azote ou d'hélium restant dans les tissus humains (sang notamment). Il entre dans le cadre des procédures de décompression en prévention des accidents de décompression (ADD). Sa profondeur et son temps sont donnés par les tables de décompression ou un ordinateur de plongée.
HémostaseL'hémostase est l'ensemble des phénomènes du sang et des vaisseaux sanguins prévenant ou permettant l'arrêt de l'écoulement du sang et ainsi, contrôlant physiologiquement le retour à une circulation normale. Une séquence d'activation physiologique et moléculaire s'enclenche pour éviter le saignement en cas de brèche vasculaire. Celle-ci aboutit à la formation d'un caillot sanguin sur son site actif (la brèche vasculaire), grâce à des processus de régulation.