Posez n’importe quelle question sur les cours, conférences, exercices, recherches, actualités, etc. de l’EPFL ou essayez les exemples de questions ci-dessous.
AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.
The design procedure, realization and measurements of an implantable radiator for telemetry applications are presented. First, free space analysis allows the choice of the antenna typology with reduced computation time. Subsequently the antenna, inserted i ...
Institute of Electrical and Electronics Engineers2011
To improve health, to help to manage chronical disease and to provide equal access to healthcare, continuous monitoring of physiological parameter associated to telemedicine is mandatory. In this perspective Body Sensor Networks concept has emerged. It inc ...
Brown adipose fat tissue of a mouse dissipates the animal’s energy in the form of heat. Chronically recording the temperature of this tissue helps biologists to study the metabolism of the animal and gain new insights about the obesity in humans. Such temp ...
We have realized an implantable and wearable system for the continuous monitoring of human metabolites, such as glucose, lactate, ATP, etc.. The implantable portion of the device consists of a cylinder of 2.2 mm in diameter and 15 mm in length to be insert ...
Small antennas, or more specifically, electrically small antennas, are passive radiating elements whose size is much smaller than the operating wavelength. The current wireless application systems usually have size constraints that, for the most common ope ...
The accuracy of approximate formulas for the evaluation of lightning electromagnetic fields above and inside a lossy ground is investigated taking as reference full-wave numerical results obtained using a parallel implementation of the finite-difference ti ...
Medical devices have gone a long way since their beginning. In the last decades, the trend has been towards Implanted Medical Devices (IMDs). The technology evolution has provided the necessary tools for longer-term, less invasive devices. Several devices ...
The average lifetime of an implanted pacemaker or defibrillator cable (lead) is approximately 10 years. One of the main lead failure mechanisms is deterioration of the insulation, which can be caused by chemical, biological, and mechanical processes. Each ...
Ceramics are known to be chemically stable, and the possibility to electrically dope polymer-derived ceramics makes it a material of interest for implantable electrodes applications. We investigated cytotoxic characteristics of four polymer-derived ceramic ...
This thesis was carried out within the framework of a scientific cooperation project entitled “Application of High Power Electromagnetics to Human Safety” developed by the EPFL, the National University of Colombia and Los Andes University, Colombia. The pr ...