Phase change behavior of ammonia-water mixtures in corrugated plate heat exchangers
Publications associées (83)
Graph Chatbot
Chattez avec Graph Search
Posez n’importe quelle question sur les cours, conférences, exercices, recherches, actualités, etc. de l’EPFL ou essayez les exemples de questions ci-dessous.
AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.
The substitution of CFC refrigerants in refrigeration systems, heat pumps and organic Rankine cycles, requests a good knowledge of the heat transfer and pressure drop properties of substitute fluids. A contribution to this international effort is proposed ...
Steam production units (HRSG and HSSG) of ISCCS include several heat exchangers (economizers, evaporator, superheater, reheaters, etc.). The knowledge of the extended composites as a function of the solar input, allows the determination of the most critica ...
This project is evaluating a heat pump cycle with midstage injection at scroll compressors. The injected refrigerant is evaporated partially by an internal heat exchanger (fig. 2.1). A glycol-water heat pump with 12 kW heat capacity at B-5/W50 was built an ...
A brine/water heat pump with the auxiliary liquid subcooling cycle with a heating capacity of 9 kW at -7/50°C was built and a series of measurement were conduced. The heat pump is designed for the monovalent heating in the retrofit market. For this purpose ...
Targeting the integration of the utility system in an industrial site, introduces the problem of combined heat and power production and more specifically the optimal integration of the steam network. We present a mathemat ical tool that allows, using only ...
Intube evaporation tests for R-407C and R-407C/oil are reported for a plain copper tube. The tests were run at a nominal inlet pressure of 6.45 bar (93.5 psia) at mass velocities of 100, 200 and 300 kg/m2s (73581, 147162 and 220743 lb/h ft2) over nearly th ...
The substitution of CFC refrigerants in refrigeration systems, heat pumps and organic Rankine cycles for heat recovery, requires good methods for predicting heat transfer of substitute fluids. The measurements in the LENI test facility (concentric tubes wi ...
The energy integration of industrial processes is becoming increasingly more effective thanks to new methodological developments such as pinch technology. This paper aims at extending the number of factors considered in pinch analysis toward a life-cycle o ...
We study the phase transition in SU(2)-Higgs model on the lattice using the 3D dimensionally reduced formalism. The 3D formalism enables us to obtain highly accurate Monte Carlo results, which we extrapolate both to the infinite volume and to the continuum ...
The pinch analysis method is a useful tool for the energy integration of industrial processes (structuring and simplification using simple guidelines). The pinch analysis method, extended to include exergy factors, falls within the framework of a global mu ...