Transverse heat transfer coefficient in the dual channel ITER TF CICCs Part I: Analysis of steady state temperature profiles resulting from annular heating
Publications associées (33)
Graph Chatbot
Chattez avec Graph Search
Posez n’importe quelle question sur les cours, conférences, exercices, recherches, actualités, etc. de l’EPFL ou essayez les exemples de questions ci-dessous.
AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.
This paper describes a new method to determine the equivalent transverse heat transfer coefficient between the helium flow in the cable bundle and the flow in the central space of a CICC's with parallel cooling channel. The method is based on the analysis ...
The attention of the fusion magnet specialists has been drawn in the last years to the volt-ampere characteristic (VAC) of the large cable-in-conduit conductors (CICC), as early voltage was observed in conductor and model coil tests, far away from the expe ...
The ab-plane optical reflectance of single crystal of Bi2Sr2Ca(Cu1-xNix)(2)O8+d, for x = 0.0215, has been measured from 80 to 40 000 cm(-l) (10 meV-5 eV) and at temperatures between 20 and 300 K. Through Ni substitution, the optical conductivity shows a br ...
This paper presents experimental results obtained at the International Center for Lightning Research and Testing (ICLRT) at Camp Blanding, Florida during the smnmers of 2002 and 2003. Currents induced by triggered and natural lightning events were measured ...
In this paper, we present a review of theoretical methods to compute lightning induced currents and voltages on buried cables. The evaluation of such induced disturbances requires the calculation of the electric field produced by lightning along the cable ...
Lightning-induced voltages in power and communication systems are nowadays one of the main causes of power quality and electromagnetic compatibility. In recent years, due to the increasing demand by customers for good quality in the power supply along with ...
We have improved the model presently used in the thermo-hydraulic code Gandalf, adapting it to cable-in-conduit conductors with central cooling channel such as those developed for the model coils of ITER, In particular the helium flow in an arbitrary numbe ...
The index n of the voltage-current characteristic of large superconductors is a crucial parameter to assess the allowed range for coil operation. In the tests of the Insert coils at the CSMC as well as in the short sample test in the SULTAN facility, it is ...
Besides the option of HTS cables as retrofit elements in densely populated areas, the technically most attractive aspect of HTS is the possibility of high power transmission at reduced voltage. In this paper we concentrate on this second aspect. High power ...
In the frame of the European Fusion Technology Programme, the Forschungszentrum Karlsruhe and the CRPP Villigen are developing a 60 kA current lead for the ITER Toroidal Field Coils using High Temperature Superconductors. In part 2 of the task, two 10 kA H ...