AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.
For an improved assessment of the indirect-lightning performances of distribution systems, the real configuration of the system, which means the topology, the presence of protection devices such as surge arresters and shielding wire/neutral groundings, mus ...
The DC performances of three full- and five sub-size NbTi cable-in-conduit conductors, measured in the SULTAN test facility, are compared. In general, the self-field effect was found to cause sudden take-offs at high currents. In most of the investigated c ...
In the last twenty years, the widespread use of sensitive electronic devices has increased the interest on transients, in particular those caused by lightning (direct and/or indirect). The paper presents first shortly the developments in modeling the elect ...
This paper deals with scale models of power distribution systems for the study of lightning induced voltages on overhead lines. The scale model technique is useful for the investigation of situations which are prohibitively complex to be treated theoretica ...
This paper deals with the assessment of the lightning performance of distribution lines, namely the estimation of the annual number of lightning-induced flashovers versus the critical flashover voltage of the line insulators. The procedure proposed by the ...
In this paper, we present a review of theoretical methods to compute lightning induced currents and voltages on buried cables. The evaluation of such induced disturbances requires the calculation of the electric field produced by lightning along the cable ...
This paper presents a new approach to model a transmission tower for lightning performance studies. It consists of representing each part of the tower by equivalent vertical and/or horizontal transmission lines as required. While horizontal line parameters ...
Lightning-induced voltages in power and communication systems are nowadays one of the main causes of power quality and electromagnetic compatibility. In recent years, due to the increasing demand by customers for good quality in the power supply along with ...
In this paper, we investigate the effect of periodically-grounded shielding wires and surge arresters on the attenuation of lightning-induced voltages. We discuss the adequacy of the commonly made simplification of assuming the shielding wire at ground pot ...
The appraisal of the response of distribution networks to the excitation of lightning electro magnetic pulse (LEMP) requires the availability of accurate models of LEMP-illuminated lines. These models should be able to take into account the presence of shi ...