A tilted grating interferometer for full vector field differential x-ray phase contrast tomography
Graph Chatbot
Chattez avec Graph Search
Posez n’importe quelle question sur les cours, conférences, exercices, recherches, actualités, etc. de l’EPFL ou essayez les exemples de questions ci-dessous.
AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.
In x-ray radiography, particularly for technical and industrial applications, a scanning setup is very often favorable when compared to a direct two-dimensional image acquisition. Here, we report on an efficient scanning method for grating based x-ray phas ...
A bundled electron beam (BEB) (14) is controlled regarding its excursion in its direction by two pairs of plate electrodes (17.1,17.2;18.1,18.2) that operate vertically to each other. The BEB can use appropriate control of these plate electrodes to scan an ...
Imaging with visible light today uses numerous contrast mechanisms, including bright- and dark-field contrast, phase-contrast schemes and confocal and fluorescence-based methods. X-ray imaging, on the other hand, has only recently seen the development of a ...
X-ray phase and absorption radiographs and tomograms of the heart of a rat were taken with an X-ray grating interferometer with monochromatic synchrotron radiation at a photon energy of 17.5 keV. The phase images show largely superior quality with respect ...
The patented Nanoconverter is as planar flexure-based structure that attenuates linear movement amplitudes by a large constant reduction factor that can be chosen by design typically between 20 and 1000. It allows using conventional commercial actuators wi ...
Substantial improvements in the nanofabrication and characteristics of gold Fresnel zone plates yielded unprecedented resolution levels in hard-x-ray microscopy. Tests performed on a variety of specimens with 8-10 keV photons demonstrated a first-order lat ...
We have developed a method for X-ray phase contrast imaging, which is based on a grating interferometer. The technique is capable of recording the phase shift of hard X-rays travelling through a sample, which greatly enhances the contrast of low absorbing ...
Digital holographic microscopy (DHM) is an interferometric technique, providing quantitative mapping of the phase shift induced by semi- transparent microscopic specimens, such as cells, with sub-wavelenght resolution along the optical axis. Thanks to actu ...
Differential x-ray phase contrast imaging using a grating interferometer was combined with a magnifying cone beam geometry using a conventional microfocus x-ray tube. This brings the advantages of a magnifying cone beam setup, namely, a high spatial resolu ...
The present thesis develops some specific aspects of digital holographic microscopy (DHM), namely the effect of shot noise on the phase image accuracy, the use of DHM in micro-tomography and in aberrations evaluation of a microscope objective (MO). DHM is ...